- 37 -
8). Make frequent checks on the electrical wires, buttons, connectors always to see if they are bitten by rats
or worms.
9). Make frequent checks on the feed pipe and drain pipe always to see if there is some parts broken or
bended make sure it is smooth.
10).when storing the products, do not put converted and overlapped, make sure they are far away from
formic acid and methanal as well as any other organic solvent.
11).if they are needed to be carried, do take those actions lightly, in case of high pressure
、
mechanical
impact strength and succession.
12).if the bathtub are not to be used for a long time, dry inside the bathtub and make the circumstance dry
and ventilated as well as no corrosive gas.
Ⅶ
. Instructions on Maintenance:
1). Replace the massage water pump: cut off power supply, open the bathtub side plate, drain empty the
SPA’s water, remove the wires and open the water pump, loosen the fixed bolts and take out the water
pump, after replacing the pump, install power wire, fix the bolts, put into small amount of water into the
bathtub, check if there’s leakage at the pump, and then install the side plate of the bathtub.
2). Replace the filter water pump: cut off power supply, open the bathtub side plate, turn off the valves on
both ends of water pump, remove the wires and open the water pump, loosen the fixed bolts and take out the
water pump, after replacing the pump, install power wire, fix the bolts, put into small amount of water into
the bathtub, turn on the valve, check if there’s leakage at the pump, and then install the side plate of the
bathtub.
3). Replace the thermostat: cut off power supply, open the bathtub side plate, turn off the valves on both
ends of thermostat, remove the wires, loosen the fixed bolts and take out the thermostat, after replacement,
install power wire, fix the bolts, put into small amount of water into the bathtub, turn on the valve, check if
there’s leakage at the pump, and then install the side plate of the bathtub.
4). Replace the filter core: cut off power supply, open the bathtub side plate, turn off the valves, loosen the
bolts on top of the filter, take out the filter, remove dirt on bottom of the filter.
5). Anti-frozen of filter: In some area, water may be frozen in winter, under this case, please stop using filter,
to remove it and clean the core, store it in safe place or move the filter core to interior. Or keep the SPA at
standby state.
Ⅷ
. Troubleshooting:
Faults
Reason
Solution
No reaction for
panel key
1. Panel was locked
2. Panel is broken
Unlock the panel
Change panel
No power supply
1. There’s problem for the power
circuit;
2. Protective switch is cut off.
Check the circuit
Check and remove short circuit, conenct
the protective switch
Nozzle doesn’t
spray water
1. There’s problem for power supply
of water pump;
2. Water pump is not started.
3. Massage water pump is damaged
4. There is air in pipe
Check and connect the power wire;
Check the massage water pump
Replace the massage water pump
Purify pipe by taking the loose joint part
Underwater lamp
doesn’t light on
1. Bulb is damaged;
2. Fuse is broken.
Replace the bulb
Replace the fuse
Poor filtering effect
1. Filter water pump is not started;
2. Filter isn’t cleaned;
3. Filter water pump is damaged.
Start the filter water pump
Clean the filter
Replace the filter water pump