Fill it up
Preparation and filling
Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling
to allow as much air as possible to escape from the plumbing and the control system during the filling process.
After turning the power on at the main power panel, the top-side panel will display a splash, or startup screen.
Priming Mode – M019*
The mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.
Regardless of whether the priming mode ends automatically or you manually exit the priming mode,the system
will automatically return to normal heating and filtering at the end of the priming mode.During the priming
mode,the heater is disable to allow the priming process to be completed without the posibility if energizing the
heater under low-flow or no-flow conditions. Nothing comes on automatically, but the pump(s) can be energized
by selecting the
“
Jet
”
buttons. If the spa has a Circ Pump, it can be turned on and off by pressing the
“
Circ
Pump
”
button during Priming Mode.