INTRODUCTION AND WELCOME 

 

It is a pleasure to welcome you to the growing number of customers who own and operate Baker laboratory 

products. As the inventors of the laminar flow biological safety cabinet and the leaders in the field, Baker 
people take special pride in providing a product that is designed for maximum performance. 

 
Your new SterilGARD

®

 e

3

 cabinet includes many unique features which are included to give you superior 

performance, more simple maintenance and lower life cycle cost. The SterilGARD

 ®

 e

3

 is a Class II, Type A2 

biosafety cabinet that provides personnel, product, and environmental protection. The SterilGARD

 ®

 e

3

 is 

suitable for research and clinical diagnostic work involving tissue culturing of possibly infectious samples, IV 
drug preparations and other pharmaceuticals that could have adverse health effects on operators and other 
techniques requiring a contamination-free atmosphere. 

 
In addition to the high quality you expect from all Baker equipment, this model has been designed to provide 

the lab user with the most comfortable work environment possible. The ergonomic design will help prevent 
repetitive motion injury, reduce fatigue and lab accidents and enhance productivity. 

 
Baker’s exclusive e3 (Energy Efficient Engineered) product line also offers reductions in noise and electrical 

power consumption without sacrificing the superior performance of a Baker cabinet. 

 
The adequacy of a cabinet for user safety should be determined on-site by an industrial hygienist, safety 

officer or other qualified person. Remember that you, the owner and user, are ultimately responsible and that 
you use your cabinet at your own risk. 

 

We recommend that this manual, along with the factory test report, be kept near the cabinet for

 

convenient 

reference by operators and qualified maintenance personnel. If you have any questions about the use or care of 
your new SterilGARD

 ®

 e

3

 cabinet, please do not hesitate to contact our Customer Service Department              

at 

1-800-992-2537

 for assistance or e-mail us at 

[email protected]

 

Sincerely, 

                      

 

David Eagleson 

President 

The Baker Company, Inc.

 

 

 
 
 

 

Summary of Contents for SterilGARD e3 Series

Page 1: ...B i OPERATOR S MANUAL Class II Type A2 Biological Safety Cabinet MODELS SG404 SG504 SG604 SG404 INT SG504 INT SG604 INT SG404 J SG504 J SG604 J Revision Date Description B 11 12 14 Changed Warranty St...

Page 2: ...ring a contamination free atmosphere In addition to the high quality you expect from all Baker equipment this model has been designed to provide the lab user with the most comfortable work environment...

Page 3: ...ea Lighting 4 Electronic Ballast 4 Ground Fault Circuit Interrupter 115V only 4 Laboratory services 4 Alarms 4 Timers 4 Padded Bypass Armrest 5 UniPressure Plenum 5 Motor Blower Assembly 5 Cable Port...

Page 4: ...increment programming 10 1 hour increment programming 10 Cable Ports 10 Cable Ports continued 11 Start up Procedure 11 Working in the Cabinet 12 Using Ancillary Equipment 13 Reacting to Spills 13 Clea...

Page 5: ...supply air passes through a diffuser but some of the air is directed down the back side of the view screen creating a high velocity air curtain at the front access opening The HEPA filtered supply air...

Page 6: ...ILTER POSITIVE PRESSURE PLENUM SUPPLY HEPA FILTER REMOVABLE WORK SURFACE AND SUPPORTS FLUORESCENT LAMP LIGHT CANOPY SLIDING VIEWSCREEN 10 DEGREE SLOPE SUPPLY DIFFUSER FILTER PROTECTOR AUXILIARY OUTLET...

Page 7: ...cabinet has a manual internal balancing damper that compensates for down flow and exhaust intake imbalances WARNING This damper must only be adjusted by a qualified technician who has had proper train...

Page 8: ...The SterilGARD e3 standard view screen access opening is 8 203 mm Other optional factory configurations available with NSF listing are 10 254 mm and 12 305 mm access openings Work Area Lighting The w...

Page 9: ...the recorded value in the most recent certification report However if drastic change is noted this should be cause for investigating the reason This device is not intended to be used for air flow set...

Page 10: ...rnia OSHPD pre approval FlexAIR Canopy Exhaust Connection CEC The FlexAIR canopy exhaust connection with integrated alarm provides the cabinet with a safe exhaust connection to building exhaust system...

Page 11: ...BMBL 5th edition published by the U S Department of Health Human Services as HHS Publication No CDC 21 1112 as an advisory document for safe work practices Baker biosafety cabinets are designed for c...

Page 12: ...e device It is recommended that the GFCI device be tested periodically to assure safe operation Ultraviolet UV Light Optional WARNING UV light is hazardous DO NOT defeat the interlock Eyes and skin sh...

Page 13: ...le Proximity Sensor Fault Alarm The Double Proximity Sensor Fault alarm occurs when both Sash Position proximity sensors are activated simultaneously This is a condition that should not be able to occ...

Page 14: ...about an additional 3 seconds you will hear a longer beep This indicates that you have turned the timer function ON are in the programming mode for the device and have programmed it to turn OFF in 1...

Page 15: ...o they cannot operate simultaneously see also step 2 5 Wipe down the interior area of the cabinet with surface disinfectant NOTE Some disinfectants such as bleach or iodine may corrode or stain the st...

Page 16: ...s in and out of the cabinet through the air barrier Room airflow can significantly affect cabinet operation Opening and closing doors in the laboratory can cause air disturbances which might interfere...

Page 17: ...ol or steel pads when cleaning stainless steel Dirt deposits on stainless steel dust dirt and finger marks can usually be removed using warm water with or without detergent If this does not remove the...

Page 18: ...riate agent prior to maintenance service or repairs in any contaminated area of the cabinet The National Institute of Health National Cancer Institute and the Centers for Disease Control have all reco...

Page 19: ...shorten the filter s life The High Efficiency Particulate Air HEPA filter is one of the essential components of a clean air cabinet It is the shield which stands between the product and the environmen...

Page 20: ...he Baker Company Inc will F O B Sanford Maine furnish without charge repairs to or replacement parts or equipment which proved defective in material or workmanship No claim may be made for any inciden...

Reviews: