TROUBLESHOOTING
Water Shut-Off Valves are Closed -
Open Shut-Off valves.
Dirty Filter -
Clean or replace filter.
Jets Not Properly Adjusted -
Adjust Jets properly.
Diverter Valve Not Properly Adjusted -
Adjust diverter valve
properly.
Thermal Overload Tripping -
Check for restricted flow of water.
Over or High Temperature Protection On -
Turn power to spa
on then off to reset.
NO, LOW OR SURGING WATER FLOW
Air Lock in Plumbing System -
“Bleed” the system.
Restricted Flow -
Insure that the water shut-off valves are open
and that suction fittings are not blocked by debris.
Dirty Filter -
Clean or replace filter.
Low Water Level -
Increase water level to recommended level.
NO LOW SPEED PUMP OPERATION
Low Level Programming Incorrect -
Contact your local dealer.
Over or High Temperature Protection On -
Turn power to spa
on then off to reset.
Pump Not Plugged-In -
Plug in the Pump.
NO PUMP OPERATION
Pump Not Plugged-In -
Plug in the Pump.
Over or High Temperature Protection On -
Turn power to spa
on then off to reset.
NOTHING OPERATES
The following describes situations and possible solutions to common problems you may encounter as a spa owner.
Main Breaker is OFF -
Set to On.
Sub-Panel Breaker Off -
Set to On.
Equipment GFCI Off -
Set to On.
Power switch in Off position -
Set to On.
Components not plugged in -
Plug in components.
Power cord not plugged in -
Plug in power cord.
Over or High Temperature Protection On -
Refer to “Error
Identification”.
NO THERAPY JET OPERATION
POWER SWITCH
Your system incorporates a power
switch. This switch will turn
power either on or off to the
internal circuitry and
connected components
Power Switch
If 3 flashing dots appear below the temperature display,
an error has occurred and a service call is needed.
If the actual spa water temperature greatly differs from the displayed
temperature or the display reads a constant 33
°
F, a temperature
(Contact Your Local Dealer for Service)
If 3 flashing dots below the temperature display and the temperature
ERROR IDENTIFICATION & SERVICE
NO HEAT
Set thermostat to a higher temperature setting. Do not expect
hot water immediately from the jets. The heater takes several
hours to raise the temperature. Check that the suction and
return valves are completely open to allow full flow of water
through the system. Clean filter if necessary to assure maximum
water flow.
NOTE:
Heater will not heat properly unless spa is covered
when not in use, with a thick insulated spa cover.
Check water chemistry for proper chemical balance, and
chlorine or bromine residual. Check to insure that filter is clean.
IF NOT, CLEAN IT! Water is filtered only while pump is running.
If necessary, change to run pump a longer period each day.
WATER DOES NOT CLEAR UP
(Contact Your Local Dealer for Service)
sensor error and a need for service has occurred.
displayed is 115
°
or higher, an over temperature condition and a
need for service has occurred.
(Contact Your Local Dealer for Service)
16
NOTE: If you notice the pump coming on for seemingly no reason
throughout the day, the system may be in “Smart Winter Mode”. If you
cannot control some functions of the spa, be sure to check to see if the
Filtration indicator is illuminated. The spa may be in the midst of a
filtration cycle. Freeze Protection and Over temperature condition will
also limit or disable spa functions.
.
.
.
.
.
.
.
.
.
If spa is reading C
°
& F
° is preferred press and hold
“Light”
button
for 5 seconds to switch
SPA READING C
°
/ F
°
SPA READING C
°
/ F
°