Jet 1 Key:
Press this key once to turn Pump 1 onto Low speed, press this key
a second time to turn Pump 1 onto High speed, a third press will turn the pump
off. A built-in timer will shut the pump off after 20 minutes of operation unless
done so manually. The Pump 1 Icon will appear in the upper LCD window while
the pump is running in High speed and flash while it is in Low speed.
Jet 2 Key:
Press this key once to turn Pump 2 onto High speed, a second press
will turn the pump off. A built-in timer will shut the pump off after 20 minutes of
operation unless done so manually. The Pump 2 Icon will appear in the upper
LCD window while the pump is running in High speed (WhiteWaterXS™ Only).
LIGHT KEY
JET 2 KEY
JET 1 KEY
JET 1 ICON
JET 2 ICON
LIGHT ICON
FILTER ICON
PROGRAM ICON
HEATER ON ICON
TEMP. SET ICON
ECONOMY ICON
PROGRAM KEY
ECONOMY KEY
TEMP. SET KEYS
Light/Enter Key:
Press this key to turn the light on, a second press will turn
the light off. The light will automatically shut off after 2 hours. The Light Icon will
appear while the light is on. Lights are preprogrammed with an assortment of light
shows. Use the spa's light key to turn
NIGHTSCAPE
on and off. When you turn
NIGHTSCAPE
off and then on again within five seconds, it advances to the next
show. When you turn
NIGHTSCAPE
off and leave it off for more then five
seconds, it “remembers” the last show you selected. The next time you turn
NIGHTSCAPE
on, it will display the same show. (See page 11 for show
schedule)
Temperature Set Keys:
Press the Up arrow key to increase the desired
temperature. Press the Down arrow key to decrease the temperature. The
temperature can be adjusted in 1°F increments from 59°F to 104°F. The new
setting will remain on the display for 5 seconds as a confirmation. During this time
the Temp. Set icon will appear to let you know this is the desired and not the actual
temperature. After 5 seconds, the display will return to the current temperature
reading. When the temperature drops to 1°F below the set temperature, the heater
will be turned on until the temperature is 1°F above the set temperature. The
Heater On icon will appear while the heater is on and flash when there is a call for
heat and the heater has not yet been activated.
SPA CONTROLLER FUNCTIONS
Default System Operation:
When power is applied, or there is a temporary loss of power, the system will initiate
its default programming.