SAFETY INSTRUCTIONS

InstRUctIons PeRtaInInG to a RIsK of fIRe, 

electRocUtIon, oR PeRsonal InJURY  

iMportant safety instructions
read and follow all instructions
saVe tHese instructions

•  risk of hyperthermia; people using medication and/or having an adverse medical history should consult a physician before using a 

hydro-thermo massage

®

 bathtub equipped with a heater or a ThermaSens

TM

 bath equipped with the warmTouchShell

TM

 technology.

•  risk of hyperthermia and possible drowning: do not use a hydro-thermo massage

®

 bathtub equipped with heater or a ThermaSens

TM

 

bath equipped with the warmTouchShell

TM

 technology immediately following strenuous exercise.

•  risk of fetal injury; pregnant or possibly pregnant women should consult a physician before using a hydro-thermo massage

®

 bathtub 

equipped with a heater, or a ThermaSens

TM

 bath equipped with the warmTouchShell

TM

 technology.

•  risk of accidental injury or drowning; do not use drugs or alcohol before or during the use of a hydro-thermo massage

®

 bathtub 

equipped with a heater or a ThermaSens

TM

 bath equipped with the warmTouchShell

TM

 technology.

• Use this unit only for its intended purposes or as described in this manual. Use only attachments recommended by the manufacturer.
•  risk of hyperthermia and possible drowning. water temperature in excess of 

100ºf (38ºc) 

may be injurious to your health. 

Check and adjust temperature before use.

•  To reduce the risk of injury, as with any other conventional bath, do not allow children or physically impaired people to use this unit 

unless they are closely supervised at all times. 

• To avoid injury, exercise care when entering or exiting the Thermomasseur

® 

or the ThermaSens

TM

.

• 

 the geysair

TM

 (option) should always be connected to the hot water intake. If it is not the case, then, the Geysair option should be 

deactivated via the bath control.

rISk oF eleCTrICal ShoCk

•  disconnect electric power before servicing.
•  do not permit electrical appliances (hair dryer, lamp, telephone, radio, television, etc.) within 

5’ (1.5 m) 

of the Thermomasseur

® 

or the ThermaSens

TM

.

•  Before using the Thermomasseur

®

 or the ThermaSens

TM

, its exterior construction (podium or skirting) should be finished so that 

a bather cannot accidentally come in contact with electrical components (turbine and power module).

•  For indoor use only.

eleCTrICal ConneCTIonS:

•  never drop or insert objects into any openings.
•  The Thermomasseur

®

 must be connected only to a supply circuit that is protected by a 

15 amp 

class a ground fault circuit interrupter 

(gfci) 

and/or 20 amps, depending on the type of Thermomasseur

®

 and options selected. BainUltra ThermaSens

TM

 must be connected 

to a circuit protected by a Class a 15 amp ground fault circuit interrupter (GFCI).

 

This interrupter is supplied by a certified electrician 

and must be tested on a regular basis in accordance with manufacturer’s instructions. The GFCI ground must be connected.  
If defective, do not use the bathtub. disconnect immediately and call a certified electrician.

•  Use 

12 awg 

(or greater) copper conductors that resist temperatures of at least 

194ºf (90ºc)

.

•  Canada only: for permanently connected units. a green-colored terminal (or a wire connector marked g, gr, ground or grounding) is 

provided within the terminal compartment (not applicable if unit supplied with an electric plug). To reduce the risk of electrocution, 
connect this terminal or connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size 
to the circuit conductors supplying the equipment and be 

12 awg 

or more.

•  all electrical connections must be carried out by a certified electrician and must respect federal, provincial/state, and localbuilding 

codes and regulations. 

•  Install in accordance with manufacturer’s installation instructions.
•  

for geysair-equipped baths

 using remote turbine installation (not mounted on the bath), grounding continuity must be tested 

between the bath grounding terminal 

 and the bath power supply. 

failure to perform the grounding continuity test could 

result in serious personal injury.

warning

1 800 463.2187 

From 8 a.m. to 8 p.m. Monday to Thursday (EST) From 8 a.m. to 5 p.m. on Friday (EST) 

Printed in Canada. Copyright © September 2012 BainUltra Inc. all rights reserved. 45100169

Some products, specifications, and services mentioned in this manual are described 

in pending patent applications or are protected by patents.

Summary of Contents for THERMASENS TMSU

Page 1: ...U TMSU TM ADDENDum to the owner s Manual Important information for the installer and the owner Included ThermoMasseur TMU Installation with AromaCloudTM thermasensTM TMSUTM Installation with AromaCloudTM Chromatherapy and WarmTouchShellTM ...

Page 2: ......

Page 3: ...Olivier Saint Nicolas Québec G7A 2N1 T 418 831 7701 1 800 463 2187 F 418 831 6623 1 800 382 8587 info bainultra com safety instructions 4 installation Bath on deck 5 Electrical installation Turbine Turbine with GeysairTM 6 Turbine with GeysairTM AromacloudTM 7 8 Turbine without GeysairTM And with AromacloudTM 9 Electrical installation THERMASENSTM 10 11 CONTRolS installation DOT controls 12 Aromac...

Page 4: ...ensTM Before using the Thermomasseur or the ThermaSensTM its exterior construction podium or skirting should be finished so that a bather cannot accidentally come in contact with electrical components turbine and power module For indoor use only electrical connections Never drop or insert objects into any openings The Thermomasseur must be connected only to a supply circuit that is protected by a ...

Page 5: ...ild the 2 x 3 wooden structure taking into account the thickness of the ceramic tiles and the plywood as well as the height of the bath NOTE Plan air intake for turbine 1 3 Secure plywood into place with screws around and above structure 1 4 Cut inside 1 1 2 of the outside dimensions of the tub 1 5 Ensure bath is levelled and that it fits properly in cutout NOTE Protect turbine and accessories as ...

Page 6: ...r connector to the grounding terminal of your electric service or supply panel with conductor equivalent in size to the circuit conductors supplying the equipment and be 12 AWG or more install this unit in accordance with the canadian electrical code part 1 A service access is necessary Minimum dimensions are 22 x 18 55cm x 46cm to properly reach all electrical components of the system GROUNDING A...

Page 7: ...hermoMasseurs Electrical outlet must be installed by a certified electrician Installation must be conducted in accordance with all local provincial state and federal building electrical codes and regulations Connect electrical power supply only after all low voltage wiring is properly installed on turbine If you did not follow this last step shut off and then restart your home s circuit breaker Tu...

Page 8: ...applications or are protected by patents 8 Supersedes page 29 of Owner s Manual electrical diagram Turbine with Geysairtm Aromacloudtm Electrical connections for Canada only TURBINE with Geysairtm aromacloudtm electrical INSTALLATION 15A CIRCUIT 20A CIRCUIT NEUTRAL N L LOAD NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTERS JUNCTION BOX AIRSTREME HEATED BACKREST A HEADREST TURBINE WITH GEYSAIR FOR...

Page 9: ... s manual electrical diagram Turbine without Geysairtm with Aromacloudtm Electrical connections for Canada only 15A CIRCUIT OR 20A IF AMMA w DOUBLE HEATED BACKREST N L N L N L N L 15A CIRCUIT NEUTRAL N L LOAD NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTERS JUNCTION BOX AIRSTREME HEATED BACKREST HEADREST TURBINE WITH GEYSAIR FOR MIA MIAPLUS MIAMULTI INMIX MODULE CHROMATHERAPY AROMACLOUDTM TURBIN...

Page 10: ...er s Manual Electrical outlet must be installed by a certified electrician Installation must be conducted in accordance with all local provincial state and federal building electrical codes and regulations Connect electrical power supply only after all low voltage wiring is properly installed on turbine If you did not follow this last step shut off and then restart your home s circuit breaker Turb...

Page 11: ... are described in pending patent applications or are protected by patents Supersedes page 29 of Owner s Manual 11 TURBINE WITH GEYSAiR electrical installation ELECTRICAL DIAGRAM ThermasensTM Electrical connections for Canada only 15A CIRCUIT AIRSTREME WARMTOUCHSHELLTM AROMACLOUDTM N L N L N L NEUTRAL N L LOAD GROUND FAULT CIRCUIT INTERRUPTER JUNCTION BOX INMIX MODULE CHROMATHERAPY Thermasenstm ele...

Page 12: ... convenient location on either the wall or the deck to install the control module or consult the specifications sheet for the suggested location To avoid drilling in an electric component always check under the deck before drilling If you have to install the control to the wall remove the protective film of sticker behind the control You can add a silicone bead to secure it LOCATION installing the...

Page 13: ... and bath skirt if present The desired direction with respect to the bath and the room entrance The possibility that the podium will require an ad ditional cutout to house AromaCloud Note that factory installation by BainUltra will always be performed for freestanding baths whose decking has been modified to house AromaCloud LOCATION 1 Push wiring through drilled holes 2 Connect the AromaCloud to ...

Page 14: ...idation Once your aromatherapy session is complete soak up the water remaining in the housing using the sponge supplied with AromaCloud to prevent it from eventu ally stagnating Never use this sponge to clean the bath or on any other surface The sponge should not be used to fill up your AromaCloud AromaCloudTM on off To turn on AromaCloud lift the lid pour water into the housing until it reaches t...

Page 15: ...IDE WarmTouchShell WTS DOT Chromatherapy DOT WarmtouchshellTM WTSTM DOT Controls user guide operating DOT WTS Press this button to start stop the WarmTouchShell tM Therapy lasts 30 minutes A led light appears on DOT control when WarmTouchShell is in function CHROMatherapy operating DOT CHROMO 1st Pressure Start Violet color appears Successive pressures Blue Green Yellow Orange Red SCAN mode Scans ...

Page 16: ...In addition to pp 55 to 65 of Owner s Manual SITUATION SOLUTIONS Check that keypad light is working Make sure breaker is on Shut off and restart breaker Check connections in the bath junction box Canada only Check that there is water in the unit and it is filled to the recommended level Make sure the water is clean and free of suspended particles limestone rust etc Check that the lid is correctly ...

Page 17: ...ing dimensional or strongly apparent natural defects for a one 1 year period from the original purchase date EXCLUSIONS The above stated limited warranty applies as long as damage is not caused by an accident abuse misuse fire insects use of abrasive products force majeure or an act of God Transport handling or installation damages are also excluded Any part that must be changed during the warrant...

Page 18: ......

Page 19: ...ittings The position of tiling flange if present The desired direction with respect to the bath and the room entrance Notes AromaCloud must be installed on bath decking After drilling verify that there is a 1 16 inch gap between the hole and the AromaCloud housing recommended steps Choose a position for AromaCloud on the bath Place the adhesive masking paper over the area of the bath where AromaCl...

Page 20: ......

Reviews: