TradiePack - User Guide v1.3
Installation & User Guide
TP Range
9
Connecting DC loads and chargers
BTLITH-TP110 and BTLITH110-24
The BTLITH-TP110 and BTLITH-TP110-24 models are equipped with 2 convenient grey Anderson plug
connectors, one accessible from the front and one on the back of the battery as shown in
Both can be used as input and outputs for charging and running loads up to 100A each. Or one plug
could be used to charge the battery and the second plug used for loads.
Charge sources could include:
-
External AC charger with grey or black Anderson connector;
-
External (regulated) solar charger with grey Anderson connector; or
-
External DC-DC charger with grey Anderson connector.
Figure 4: BTLITH-TP110 and BTLITH-TP110-24 Front and Rear Grey Anderson Plugs
For connected chargers and devices, a grey or black Anderson plug must be used. Check to ensure the
Anderson is correctly wired (positive and negative) and do not attempt to use any coloured Anderson
other than grey.
NOTE
–
The internal BMS on the BTLITH-TP110 and BTLITH-TP110-24 is designed for up to 100A
continuous charge and 100A continuous discharge. Please consider this when connecting charging
devices and loads.
Parameter
Value
Max. Current per Grey Anderson
100 A
Max. Total Current input/output
100 A (Including Grey Andersons, Inverter and
Aux. outputs)
Table 1: BTLITH-TP110 and BTLITH-TP110-24 Grey Anderson specifications