5-9
General
5
5.4.4
FAULT -
Water flows from hot tap but has reduced flow from cold
Cause
Cure
Cold water pipe kinked preventing flow
Check and re-route if necessary
Blockage in cold pipe line
Disconnect pipes after 1st Y connector and
check up to tap
Cold tap not connected
Refer to installation instructions
Cold tap failed or blocked
Disconnect and inspect
If a Carver Crystal water service unit is
fitted the cartridge is exhausted
Replace cartridge
5.4.5
FAULT -
Reduced flow from both hot and cold taps
Cause
Cure
Battery condition low causing pump to run
Check battery state of charge refer to electrical
slowly
supply note
If new taps have been fitted they may be
Disconnect and check that they have at least Ø
restricting flow
(6.3mm) bore
Pump needs servicing
Refer to pump servicing instructions
Partially blocked pump filter or in-line
filter, if fitted
Replace filter
Pump outlet pipe kinked restricting flow
Check and re-route if necessary
Water leak
Check all water connections
5.4.6
FAULT -
Reduced flow from either taps
Cause
Cure
‘Y’ connector(s) fitted incorrectly
Refer to installation instructions
Pipe kinking restricting flow
Check and re-route if necessary
Bore size difference in taps
Use taps of equal bore size
5.4.7
FAULT -
Water Heater pressure relief valve venting water
Cause
Cure
Pressurised water system pump switching
Refer to water supply note
pressure too high
Switched tap water system pump flow rate
Refer to water supply note
is greater than tap flow rate capacity
Summary of Contents for Orion
Page 1: ...Owners Manual ...
Page 3: ......
Page 7: ......
Page 15: ...1 8 1 Introduction ...
Page 85: ...4 42 4 Caravan Equipment ...
Page 101: ...6 2 6 Index ...
Page 102: ......