47
Chapter 3
CARAVAN SERVICE SYSTEMS
THE ELECTRICAL SYSTEM – 12 VOLT
These units provide, via 230 volt AC, a 12 volt DC supply to the 12 volt
equipment and charging of the caravan battery. Maximum is 10 amps
and incorporates full automatic charging regulation. This means only the
current the battery needs will be supplied, overcharging will not occur.
Ensure that a mains supply is available via the mains inlet socket located
in the battery box compartment and that the RCD/MCB switches are in
the UP position.
12 volt power will now be available to the main control panel.
The battery charger will only function satisfactorily if the battery is in
good condition.
Should a battery contain a faulty cell the charge voltage from the battery
charger will not rise sufficiently to switch the battery charger off and the
battery will eventually boil dry.
The most common cause for batteries to become faulty is when the battery
is discharged below the recommended level, approximately 10V, causing
one or more of the cells to fail.
Summary of Contents for 2002 PAGEANT Auvergne
Page 1: ...Bailey of Bristol 2002 Series Owners Manual ...
Page 2: ......
Page 15: ...9 Chapter 2 CARAVAN TOW VEHICLE MAYBE NO YES EQUAL 85 ...
Page 52: ...46 Chapter 3 CARAVAN SERVICE SYSTEMS ...
Page 57: ...51 Chapter 3 CARAVAN SERVICE SYSTEMS CONTROL PANEL SPB2 ...
Page 135: ...129 Chapter 5 GENERAL ASSEMBLING THE BUNKS 2 1 5 4 3 6 ...
Page 146: ...140 Chapter 6 TECHNICAL INFORMATION 230 VOLT 12 VOLT PRIMARY CIRCUIT DIAGRAM RANGER ...
Page 147: ...141 Chapter 6 TECHNICAL INFORMATION 230 VOLT 12 VOLT PRIMARY CIRCUIT DIAGRAM SENATOR ...
Page 160: ...154 Chapter 6 TECHNICAL INFORMATION NOTES ...
Page 161: ...155 Chapter 6 TECHNICAL INFORMATION NOTES ...
Page 163: ......
Page 164: ...Bailey of Bristol South Liberty Lane Bristol BS3 2SS England www bailey caravans co uk ...