Figure 3-21: Reboot
3.7.9 Verify eNB Operational Status
When the eNB is finished rebooting, check the eNB status using the eNB GUI and the OMC. Once
the eNB is mounted at its intended destination and powered on, recheck the status settings.
•
eNB
GUI
: Go to
Basic Setting > Basic Info
and check the
Cell Status
field (Figure 3-22). It
should show
Active
. Also, check that
GPS Sync
is reported as
Synchronized
.
•
OMC:
Go to
eNB > Monitor
to see if the
Cell Status
shows
Active
and the
Sync Status
shows
GPS Synchronized
NOTE: Ensure you have selected ALL in the display settings window in the
OMC > eNB > Monitor
page to view
Cell Status
and
Sync Status