M-Bus Interface Module XC 

User Manual

 

Page 3 from 6 

E110003813092 

Bär Industrie-Elektronik GmbH 

 Rathsbergstr. 23 

 D-90411 Nürnberg 

 Phone +49 911 970590 

 Fax +49 911 9705950 

 

 

Communication 

The interface port is conforming to IEC 62056-21 with fixed baud rate. For setting the baud rate use 
please the EMH COMBI-TOOL-Software: menu 

Meter 

 Interfaces 

 Electrical interface

For reading data the meter-ID (device address) can be used (e.g. /?<meter-ID>!). 
Explanations of massage contents (see IEC 62056-21): 

  Start character: / (forward oblique, code 2F

Hex

  End character: ! (exclamation mark, code 21

Hex

  Completion character: CR (carriage return, code 0D

Hex

) and LF (line feed, Code 0A

Hex

); enter key 

Example for communication path:  
Sign-on sequence:  

 

/?! CR LF  

without meter-ID   

or 

/?12345678! CR LF  

if the meter-ID := 12345678 

Answer: 

/EMHzIdent CR LF 

z := baud rate identification 

Sign-on acknowledgement: 

ACK 0z0 CR LF 

Data readout (billing list): 

/EMH5\@\201LZQJL001VE 

F.F(00000000) 
0.0.0(12345678) 
0.1.0(03) 
0.1.2*03(0120216091536) 
0.1.2*02(0120101000000) 
0.1.2&01(0111209125955) 
… 
0.2.2(00000024) 
0.9.1(0155843) 
0.9.2(0120216) 
1.2.1(0010.09*kW) 
2.2.1(0000.00*kW) 
… 

 

 

Possible telegrams (for more information see please the meter manual): 

  Billing list:  

sign-on sequence:  /?! 

  Table 1:  

sign-on sequence:  /1! 

  Table 2:  

sign-on sequence:  /2! 

  Table 3:  

sign-on sequence:  /3! 

  Table 4 (service data):   sign-on sequence:  /4! 

  Load profile P.01 

  User profile P.02 

  Log book P.98 

  PTB log book P.99 

  User log book P.200 

 
Option: DLMS protocole; 