Faults/troubleshooting
52 EN
03|2022
Problem:
Pump is still in operation following backwash/rinse and
actuator remains in this position (pool is drained).
Possible causes
Solution
Relay overloaded or stuck.
Î
Tap the relay lightly with
the finger.
Î
Send the actuator with
valve lid to the
manufacturer.
Î
VS pumps should only be
wired via the control
cable.
Problem:
Small, blue sprocket is faulty (as seen from the side of
the mechanism; the sprocket is not picked up).
Possible causes
Solution
Valve insert overloaded.
Î
Send the actuator with
valve lid to the manu-
facturer for inspection.
Electrical connection fault at
the pump.
Î
Check electrical
connections using the
operation manual.
Unfavourable installation
conditions (height difference).
Î
Check the installation
situation; if necessary
integrate a special SPECK
non-return valve
(240.9102.063).
Notice:
The sprocket on the motor can be replaced by
experienced repair companies (in this case the manufacturer’s
warranty is no longer valid). The motor is removed upwards. The
blue sprocket and a heavy duty dowel pin are necessary parts.
Following replacement, the device starts as usual.
The replacement is explained again
graphically in this video.
Summary of Contents for OmniTronic
Page 3: ...DE Originalbetriebsanleitung OmniTronic WG26 150 010 P...
Page 66: ......
Page 67: ...EN Translation of original operation manual OmniTronic WG26 150 010 P...
Page 126: ......
Page 127: ...FR Traduction des instructions d utilisation originale OmniTronic WG26 150 010 P...
Page 193: ...NL Vertaling van de oorspronkelijke gebruikershandleiding OmniTronic WG26 150 010 P...
Page 256: ......
Page 257: ...IT Traduzione del manuale d istruzioni originali OmniTronic WG26 150 010 P...
Page 321: ...ES Traducci n de las instrucciones originales para el manejo OmniTronic WG26 150 010 P...