Installation
44 EN
03|2022
5.3.3 Connection diagram
Fig. 7
To connect the cables, first pull the plug off the pin header
upwards. The wires with press-fit wire end ferrules can therefore
be inserted conveniently under the orange opening points without
tools.
The tone signal can be set quieter and louder by replugging the
plugged bridge underneath the connections for the VS-pump. The
plugged bridge can also be removed if necessary. The tone signal
is then no longer available.
3 digital inputs with 230 V
N, AC1, AC2, AC3
3 potential-free digital inputs
DNG, DCx
2 relay outputs
Z1, Z2, Z_, 11, 14, 12
Pump (max. 4 A) with
asynchronous motor
Lp, Np
Supply
L, L, N, N
BADU Eco VS or
BADU Eco Touch-Pro
control cable
ground, rd, br, gr, wh
Level sensor
(optional)
(PE distributor terminal
present)
31
5
mA
T
4
AT
WG27.50.118-2-P
Sensor 3
GND
Sensor 2
Tone signal volume
Summary of Contents for OmniTronic