18
4. Operating mode
In the menu “4. Operating mode” the con
-
troller can either be placed in automatic
mode, switched off or placed in a manual
operating mode.
The menu is closed by pressing the “esc”
key or selecting “Exit operating mode”.
Operating mode
Automatic mode is the normal operating mode of the controller. Only automatic mode
provides proper controller function taking into account the current temperatures and
the parameters that have been set! After an interruption of the mains voltage the con
-
troller automatically returns to the last operating mode selected!
4.1. Automatic
4.2. Manual
The relay and thus the connected consumer are switched on and off, with no regard
to the current temperatures and the parameters which have been set, by pressing a
key. The measured temperatures are also shown to provide an overview and function
control.
Danger
When the operating mode “Manual” is activated, the current tempera
-
tures and the selected parameters are no longer considered. There is a
danger of scalding or serious damage to the system. The operating mode
“Manual” may only be used by specialists for brief function tests or during
commissioning!
4.3.
Off
When the operating mode “Off” is activated, all controller functions are
switched off. This can lead, for example, to overheating on the solar col
-
lector or other system components. The measured temperatures are still
displayed to provide an overview.