5
.3 Removing the Inverter
Perform the following procedures to remove the inverter:
Step 1. Disconnect all cables from the inverter, including communications cables, DC input
power cables, AC output power cables, and protective ground (GND) cable, as shown below.
Step 2. Remove the inverter from the mounting bracket.
Before removing DC input connector, double check DC input switch is turned
to OFF to avoid inverter damage and personal injury.
NOTE
To remove the PV/Grid/EPS connectors,
insert the removal tool
into the lock
according to the position indicated in the
drawing, press inward, and then
remove
the connector
.
Grid/EPS Connectors Removing Detail
PV Connectors Removing Detail