Badger Power Electronics
2
.10 Wi
-
Fi Datalogger Connection
This datalogger is used for connecting to Wi-Fi to use Solarman online monitoring.
Loose
n the
two screw and
remove the cover.
a
Insert WI
-
FI datalogger into W
-
IFI port, and tighten the two screws.
b
2 x M4 screws; 0.8N.m
Connect and tighten the cable between
the WIFI datalogger and the external
f
e
Install the external Antenna.
Close and lock the door of the system
enclosure
.
d
Antenna.
c
Tighten the two M4 screws with 0.8N.m torque.
3
System Operation
3
.1 Inverter Working Mode
s
The
PowerDepot Hybrid Inverter
supports several different working modes
which can be programmed on the SolarHope
App
.
3
.1.1 Self Used Mode
Go to the "Hybrid
W
ork
M
ode" menu, and select the "Self
U
sed
M
ode" wor
k
mode.
Under Self Used
M
ode, the priority
of PV energy will be Load > Battery > Grid, that means the energy produced by PV gives priority to local loads, excess
energy is used for charging the battery, and the
remaining energy is fed into the grid.
This is the default mode to
increase
the
self-consumption rate.
a)
Excess
PV Energy
When
there is plenty
PV energy
available
, the PV energy will be first consumed by loads, the
excess energy will be
used to charge the battery.
T
hen
,
the remaining energy will be fed into the grid.
EPS
1
3
2
1 2 3
is the sequence of PV energy transmission.
1
BAT
PV
GRID
EPS
COM
ALARM
b) Limited PV power
When the PV energy is not enough to cover all the loads, all the PV energy will be used for load, and the
remaining
part
will be supported by
the
battery.
If this does not satisfy the load, more power will be taken from the Grid.
15