![Badger Meter SDI Series User Manual Download Page 23](http://html1.mh-extra.com/html/badger-meter/sdi-series/sdi-series_user-manual_3402515023.webp)
Power Specifications
Number of Wire Connections
Unidirectional
Bidirectional
Battery
Operated
Raw Pulse
Option 0
Analog Loop
Option 1
Scaled Pulse
Option 2
Analog Loop
Option 5
Scaled Pulse
Option 6
Scaled Pulse
Option 2
2
2
4
6
6
2
Pulse
Units
Operating Voltage
8…35V DC
n/a
12…30V AC
12…35V DC
12…30V AC
12…35V DC
12…30V AC
12…35V DC
n/a
Overvoltage
Protection
30V AC
± 40V DC
± 40V DC
30V AC
± 40V DC
30V AC
± 40V DC
30V AC
± 40V DC
n/a
Quiescent Current
Draw
@ 12V DC or 24V AC
330 µA typical
Software-controlled
current of
3 .5…20 .5 mA
< 2 .0 mA
< 5 .0 mA
< 5 .0 mA
n/a
Short Circuit Current 50 mA typical
n/a
> 100 mA
For direction >
100 mA
> 100 mA
> 100 mA
Output Frequency
800 Hz max
n/a
Scaled by
customer
n/a
Scaled by
customer
Scaled by
customer
Output Pulse Width
5 mS below
100 Hz
n/a
Adjustable
50 mS to 5 .0
seconds in
50 mS
increments
n/a
Adjustable
50 mS to 5 .0
seconds in
50 mS
increments
Selectable
50 mS
100 mS
250 mS
Output Isolation
n/a
n/a
Opto-isolated
Opto-isolated
Opto-isolated
Opto-isolated
Analog
Units
Operating Voltage
n/a
8…25V DC
n/a
8…25V DC
n/a
n/a
Output Response
Time
n/a
Varies with
programmable filter
n/a
Varies with
programmable
filter
n/a
n/a
The battery powered version is powered by a “C” size lithium battery with a five year life span
Specifications
Page 23
May 2017
SEN-UM-00217-EN-10