8. Technical data
8.1 Detector type II
Technical data
Size
DN 6 – 1400 (1/4“...56“)
Process connections
Flange: DIN, ANSI, JIS, AWWA etc.
Nominal pressure
Up to PN 100
Protection class
IP 65, optional IP 68
Min. conductivity
5 µS/cm (20 µS/cm for demineralized water)
Hard-/soft rubber
from DN 25
0 up to +80°C
Liner materials
PTFE
DN 6 - 600
-40 up to +150°C
Halar (ECTFE)
from DN 300
-40 up to +150°C
Electrodes materials
Hastelloy C (standard)
Tantalum
Platinum/Gold plated
Platinum/Rhodium
Housing
Carbon steel/optional stainless steel
DN 6 – 20
170 mm
DN 25 – 50
225 mm
DN 65 – 100
280 mm
DN 125 – 200
400 mm
DN 250 – 350
500 mm
DN 400 – 750
600 mm
DN 800 – 1000
800 mm