![Badger Meter Oval Gear LM OG Series User Manual Download Page 22](http://html1.mh-extra.com/html/badger-meter/oval-gear-lm-og-series/oval-gear-lm-og-series_user-manual_3739768022.webp)
Seite / Page / Page 22
April/April/Avril 2023
AUT-UM-03446-DE-02
LM OG Baureihe / LM OG Series / Série LM OG
PROGRAMMING THE LM OG-AM AND LM OG-TAERM
LM OG-A (CND)
The units of measure and the correction factor can be configured in the programming mode . A program button on the
backside of the register will enable the mode, only accessible when the register has been removed from the meter . Removing
the register from the meter will break the sealing . This seal has to be restamped by the national authorities (MID) .
01
Turn on the register by pressing the
TOTAL
button .
08
The fifth number can now be changed .
To move forward, press
TOTAL
again .
02
Press the programming button on the
backside of the register to enter the
programming mode .
09
The arrow for the flow direction flashes
now . Use
RESET
to change or
TOTAL
to
move forward .
03
The measuring unit will flash and can be
changed by pressing the
RESET
button
(L, GAL, QT, PT) .
To move forward, press the
TOTAL
button .
10
Press the programming button on the
backside of the register to quit the
programming mode .
04
Press
TOTAL
to change the k-factor . The
number to be changed is flashing and can
be modified with
RESET
.
To change the next number, press
TOTAL
.
11
The register goes into the sleep mode .
05
The second number can now be changed .
To move to the next number, press
TOTAL
again .
12
To wake up the register, press the
RESET
button .
06
The third number can now be changed .
To move to the next number, press
TOTAL
again .
13
Press
RESET
for 3 seconds and the
register displays the checksum and serial
number in the bottom line .
07
The fourth number can now be changed .
To move to the next number, press
TOTAL
again .