Switch from Totalizer (l) to Flow Rate (l/min)
Press and hold
RESET
button .
Then press
TOTAL
.
To switch back the programming to the totalizer, press
RESET
.
Change Pulse Rate
Press
TOTAL
3 times then press
RESET
3 times (quickly) .
You are now in programming mode .
Then press and hold
TOTAL
.
The figure to be changed is flashing and can be modified with
RESET
.
To change the next figure press
TOTAL
.
Press
TOTAL
+
RESET
simultaneously to save the programming .
Currently programmed pulse rate: 100 .00 PPL
Predefined pulse rates:
1/2" = 100 ppl
3/4" = 61 .5 ppl
1" = 61 .5 ppl
1-1/2" = 17 ppl
6-digit Totalizer with Two Decimal Places
An additional 6-digit totalizer with 2 decimal places can now be called up in the register .
Press and hold
TOTAL
.
Current Totalizer: 0 .04L