AUT-UM-00933-EN-06
Meter Buttons
METER BUTTONS
Used to enter the batch quantity to be dispensed .
Used to display the accumulated total of fluid dispensed as well as the
re-settable total during
Auto Batch
and
Manual Mode
.
Used to enter and exit the
Manual
or
Auto Batch
mode .
• Used in the
Manual
mode to clear the dispensed quantity .
• Used in the
Auto Batch
mode to clear the dispensed quantity and
reset the meter for the next batch .
• Used to reset the re-settable total dispensed while pressing the
TOTAL button .
Used to stop the flow through an
Emergency Override
.
Table 1: Button locations and descriptions
LCD DISPLAY
1
2
3
4
5
6
7
1 . Displays
Re-settable Total
,
Accumulated Total
and
Scale Factor
.
2 . Displays
Unit of Measure
.
3 . Arrow- not used .
4 . Preset batch quantity .
5 . History icon- not used .
6 . Auto is an indicator of unit being in
Auto Batch Mode
.
7 . Low battery icon .
Table 2: LCD display description
METER INSTALLATION
Relieve System Pressure
THIS EQUIPMENT STAYS PRESSURIZED UNTIL THE PRESSURE IS MANUALLY RELIEVED.
1 . Turn off the power supply to the pump or close the shutoff valve .
2 . Dispense any fluid in the system into a waste container by opening the meter .
3 . Open all bleed-type master air valves and fluid meter in the system .
4 . Leave the meter open until ready to pressurize the system .
To reduce the risk of injury from fluid spray from the meter, follow this procedure when you:
• Are instructed to relieve pressure .
• Stop dispensing .
• Check, clean or service any system equipment .
• Clean or install nozzles .
Page 4
April 2019