Electronic Preset Meter, Model EPM2-STD, Standard Series

 

1

2

3

Figure 18:  Parts: inside meter

Item

Description

Part Number

1

Valve assembly

64103-010

2

Gear service kit with O-ring

62896-001

3

Trigger Assembly

64103-005

Table 7:  Part numbers: inside meter

TROUBLESHOOTING

RELIEVE THE PRESSURE PRIOR TO CHECKING OR REPAIRING THE METER. MAKE SURE ALL VALVES, CONTROLS AND 

PUMPS ARE OPERATING CORRECTLY.

Symptom

Possible Cause

Remedy

Battery icon is displayed

Batteries are low

Replace batteries

Display blank

Meter asleep

Press 

RESET

Loose battery connection

Remove battery pack and check battery connection / 

press 

RESET

Batteries dead

Replace batteries / press 

RESET

Meter does not latch  

for batching

Meter not in 

Auto Mode

Press 

AUTO

 and program the batch size

Meter not reset after prior batch

Press 

RESET

Low batteries

Check for battery icon / replace batteries / press 

RESET

Slow or no fluid flow

Filter is clogged

Clean or replace the filter in the swivel nut

Pump pressure is low

Turn up the pump pressure

Foreign material is jamming meter

Contact your local distributor for repair

Meter inaccurate

Scale Factor not correct for fluid

Enter 

Program Mode

, check and reset  

the Scale Factor

www.badgermeter.com

Trademarks appearing in this document are the property of their respective entities . Due to continuous research, product improvements and enhancements, Badger Meter reserves 

the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists . © 2019 Badger Meter, Inc . All rights reserved . 

Control. Manage. Optimize.

The Americas | Badger Meter

 | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V.

 | Pedro Luis Ogazón N°32 | Esq . Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Eastern Europe Branch Office (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus)

 | Badger Meter Europe | ul . Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787

Europe, Middle East and Africa | Badger Meter Europa GmbH

 | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe

 | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 

Slovakia | Badger Meter Slovakia s.r.o.

 | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter

 | 80 Marine Parade Rd | 19-07 Parkway Parade | Singapore 449269 | +65-63464836

Switzerland | Badger Meter Swiss AG

 | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11 

Legacy Document Number: IOM-170-03-EN 53400-170

Summary of Contents for Oval Gear EPM2-STD

Page 1: ...Electronic Preset Meter Model EPM2 STD Standard Series AUT UM 00933 EN 06 April 2019 User Manual...

Page 2: ...6 Auto Batch Mode 7 Operating Mode Functions 7 Re settable and Accumulated Totals 7 Emergency Override 7 Error Codes 7 Service 8 Low Battery 8 Changing the Batteries 8 Change Factory Settings 8 Verify...

Page 3: ...purpose Do not modify or alter the equipment Do not leave equipment unattended while dispensing Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum work...

Page 4: ...Accumulated Total and Scale Factor 2 Displays Unit of Measure 3 Arrow not used 4 Preset batch quantity 5 History icon not used 6 Auto is an indicator of unit being in Auto Batch Mode 7 Low battery ico...

Page 5: ...nd move towards the pump 1 Close fluid dispense valves at every position 2 Once the main fluid outlet valve at the pump is closed and the air pressure to the pump motor is properly adjusted the air va...

Page 6: ...n shutoff valves Start the pump to pressurize the system 4 Before use to ensure accuracy purge all air from the fluid lines and dispense valve s Figure 5 Tighten nozzle with wrench METER OPERATION NOT...

Page 7: ...NS These functions operate the same in Manual Mode and Auto Batch Mode Re settable and Accumulated Totals The meter has two flow totalizers Re settable Total and Accumulated Total 1 Press and hold TOT...

Page 8: ...OTE N Changing the batteries does not affect any of the programmed values or totals Figure 10 Replacing the batteries CHANGE FACTORY SETTINGS Each meter is calibrated at the factory for use with motor...

Page 9: ...o 0 3 Press RESET to advance to the next digit in the scale factor 4 Repeat steps 2 and 3 for all five digits Scale factor digits Figure 13 Scale factor display Save Changes To save changes and exit p...

Page 10: ...y shows 4 00 You get an error factor of 1 05 4 The existing Scale Factor is 1 0123 as shown in steps 1 and 2 in Verify Changes 5 To calculate a new factor 1 0123 existing Scale Factor x 1 05 error fac...

Page 11: ...utlet connections 1 2 in NPT 1 2 in BSPP Minimum and maximum flow range will vary with fluid viscosity Table 4 Part numbers inside meter PARTS 1 2 Figure 16 Parts back of meter Figure 17 Parts front o...

Page 12: ...Trademarks appearing in this document are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product...

Reviews: