Specifications 

SPECIFICATIONS

Maximum flow *

10 gpm (38 lpm)

Minimum flow *

0 .25 gpm (1 lpm)

Operating pressure (maximum)

1000 psi (67 bar)

Operating pressure (minimum)

5 psi (0 .35 bar)

Operating temperature (maximum)

120° F (50° C)

Operating temperature (minimum)

20° F (–5° C)

Accuracy (general)

± 0 .5%

Accuracy (anti-freeze)

± 1 .5%

5-digit LCD display

Quarts, Pints, Gallons, Liters

Inlet and outlet connections

1/2 in . NPT (1/2 in . BSPP)

* Minimum and maximum flow range will vary with fluid viscosity

Table 4:  Part numbers: inside meter

PARTS

 

 

1

2

Figure 16:  Parts: back of meter

Figure 17:  Parts: front of meter

Item

Description

Part Number

Item

Description

Part Number

1

Battery holder assembly

64103-026

1

Display assembly

64103-023

2

Bottom case with screws

64103-003

2

EPM2 std . register assembly

64103-024

Table 5:  Part numbers - back of meter

Not shown

Swivel, NPT, special fluids

64082-001

Not shown

Rubber boot

65546-001

Table 6:  Part numbers - front of meter

Page 11 

April 2019

Summary of Contents for Oval Gear EPM2-STD

Page 1: ...Electronic Preset Meter Model EPM2 STD Standard Series AUT UM 00933 EN 06 April 2019 User Manual...

Page 2: ...6 Auto Batch Mode 7 Operating Mode Functions 7 Re settable and Accumulated Totals 7 Emergency Override 7 Error Codes 7 Service 8 Low Battery 8 Changing the Batteries 8 Change Factory Settings 8 Verify...

Page 3: ...purpose Do not modify or alter the equipment Do not leave equipment unattended while dispensing Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum work...

Page 4: ...Accumulated Total and Scale Factor 2 Displays Unit of Measure 3 Arrow not used 4 Preset batch quantity 5 History icon not used 6 Auto is an indicator of unit being in Auto Batch Mode 7 Low battery ico...

Page 5: ...nd move towards the pump 1 Close fluid dispense valves at every position 2 Once the main fluid outlet valve at the pump is closed and the air pressure to the pump motor is properly adjusted the air va...

Page 6: ...n shutoff valves Start the pump to pressurize the system 4 Before use to ensure accuracy purge all air from the fluid lines and dispense valve s Figure 5 Tighten nozzle with wrench METER OPERATION NOT...

Page 7: ...NS These functions operate the same in Manual Mode and Auto Batch Mode Re settable and Accumulated Totals The meter has two flow totalizers Re settable Total and Accumulated Total 1 Press and hold TOT...

Page 8: ...OTE N Changing the batteries does not affect any of the programmed values or totals Figure 10 Replacing the batteries CHANGE FACTORY SETTINGS Each meter is calibrated at the factory for use with motor...

Page 9: ...o 0 3 Press RESET to advance to the next digit in the scale factor 4 Repeat steps 2 and 3 for all five digits Scale factor digits Figure 13 Scale factor display Save Changes To save changes and exit p...

Page 10: ...y shows 4 00 You get an error factor of 1 05 4 The existing Scale Factor is 1 0123 as shown in steps 1 and 2 in Verify Changes 5 To calculate a new factor 1 0123 existing Scale Factor x 1 05 error fac...

Page 11: ...utlet connections 1 2 in NPT 1 2 in BSPP Minimum and maximum flow range will vary with fluid viscosity Table 4 Part numbers inside meter PARTS 1 2 Figure 16 Parts back of meter Figure 17 Parts front o...

Page 12: ...Trademarks appearing in this document are the property of their respective entities Due to continuous research product improvements and enhancements Badger Meter reserves the right to change product...

Reviews: