Electronic register
page 8/11
IND_MNMR100_Bedienungsanleitung_0703_e.doc
e) Press DISP to go to the next digit. To change press RESET.
Note : Total number 999.9.
f) Press and hold down RESET until “program” disappears to accept setting.
g) Press RESET for five seconds to return the meter to the operating mode.
4.5 Display
41 SLEEP MODE = SLP 41 (set sleep mode) diSP4
a) Press and hold down RESET for 5 seconds until “MEtr 1” appears.
b) Press the DISP button 3 times to reach “diSP 4”.
c) Press RESET “SLP41” will appear.
d) Press and hold down RESET for 2 seconds (program will appear)
e) Press RESET to select sleep setting (no sleep, sleep1, sleep2, shelf).
Note: sleep 1 = micro sleep but the LCD is awakef). Press and hold down RESET
until “program” disappears to accept setting.
g) Press RESET for five seconds to return the meter to the operating mode.
42 TIME = tiME 42
(set sleep time delay = works with sleep 2 only)
a) Press and hold down RESET for 5 seconds until “MEtr 1” appears.
b) Press the DISP button 3 times to reach “diSP 4”.
c) Press RESET twice “tiME 42” will appear.
d) Press and hold down RESET for 2 seconds (program will appear).
e) Press RESET to select sleep time (1-10 minutes).
f) Press and hold down RESET until “program” disappears to accept setting.
g) Press RESET for five seconds to return the meter to the operating mode.
43 UNIT = unit 43 (set sleep wake up default display)
a) Press and hold down RESET for 5 seconds until “MEtr 1” appears.
b) Press the DISP button 3 times to reach “diSP 4”.
c) Press RESET 3 times “unit 43” will appear.
d) Press and hold down RESET for 2 seconds (program will appear).
e) Press RESET to select required display (batch, reset total, total, rate).
f) Press and hold down RESET until “program” disappears to accept setting.
g) Press RESET for five seconds to return the meter to the operating mode.
44 TIME = tiME 44 (set time for sleep default)
Time for micro to sleep (sleep1).
a) Press and hold down RESET for 5 seconds until “MEtr 1” appears.
b) Press the DISP button 3 times to reach “diSP 4”.
c) Press RESET 4 times “tiME 44” will appear.
d) Press and hold down RESET for 2 seconds (program will appear).
e) Press RESET to select default time (5-20 seconds).
f) Press and hold down RESET until “program” disappears to accept setting.
g) Press RESET for five seconds to return the meter to the operating mode.