3
Installation
Wiring Instructions
Panel Installation
Slide the included gasket over the rear of the unit. Place the unit in the panel through a 33mm x 68mm cutout. Use the
provided panel mount screws to tighten the mounting clips until there is a secure seal against the gasket. Do not over tighten.
Slide the mounting clips into the grooves in the side of the ER10.
Du ran t
Recommended
Panel Cutout
2.677" (68mm)
1.299"
(33mm)
RST
T / R
8-digit LCD
Display
®
FRONT VIEW
Reset/
Programming
button
Plastic
front panel
sealed to
meet
NEMA 4X
Mode select/
Programming
button
Gasket Installed
Install mounting clip
Transmitter
Connections
TRANSMITTER CONNECTIONS
For connecting to Badger Meter transmitters,
refer to the
Industrial Technical Brief (ITB) for your specific transmitter,
and the chart to the right. "Connections" refers to the wires
on the transmitter. The numbers in parenthesis refer to the
terminal numbers on the ER-10. Connect the wire coming
from the transmitter to the corresponding terminal number
for the ER Remote models.
To connect a generic reed switch
to the ER-10, connect
one of the wires to terminal 1. Connect the remaining wire
to terminal 2.
To connect a generic NPN transmitter
to the ER-10, con-
nect the emitter to terminal 1. Connect the collector to ter-
minal 2.
FT1 (1/2" OP)
Black (1)
Black (2)
FT1
White (1)
White (2)
FT2
White (1)
White (2)
FT420
Pulse Output
Pulse Output
Terminal – (1)
Te (2)
MSE1
Black (1)
Red (2)
MSE5
Black (1)
Red (2)
PFT2
White (1)
White (2)
PFT3
White (1)
White (2)
PFT420
Pulse Output
Pulse Output
Terminal – (1)
Te (2)
PFT420/2
Pulse Output
Pulse Output
Terminal – (1)
Te (2)
PM5
Black (1)
Red (2)
Terminal
1
2
3
4
5
6
7
Function
Ground
Input B
Count Input
Reset
Program
Enable
Backlight
Common
Backlight
Power
Operation
Count Input
Contact Closure or NPN 100 Hz. Max.
Not Used
Connect to Ground to Reset
Totalizer. This is a maintained or
Level Sensitive Reset.
Connect to Ground to Enter
Program Mode
Connect to Power to Light Display
5 Enable/R
5 Enable/R
RST 4
IN B 2
GND 1
6 DC Common
7 +10-30VDC
7 +10-30VDC
Reset
Count Input
Ground
Program enable
REAR VIEW