Badger Meter Blancett B2800XP User Manual Download Page 20

Flow Monitor, B2800XP Explosion Proof Flow Monitor Advanced

www.badgermeter.com

BLANCETT is a registered trademark of Badger Meter, Inc  Other trademarks appearing in this document are the property of their respective entities  Due to continuous research, 

product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding 

contractual obligation exists  © 2017 Badger Meter, Inc  All rights reserved  

Control. Manage. Optimize.

The Americas | Badger Meter

 | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V.

 | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Eastern Europe Branch Office

 

(for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus)

 | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787

Europe, Middle East and Africa | Badger Meter Europa GmbH

 | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe

 | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 

Slovakia | Badger Meter Slovakia s.r.o. 

| Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter

 | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter

 | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412

Switzerland | Badger Meter Swiss AG

 | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11 

Legacy Document Number:02-DSY-PM-00113

Summary of Contents for Blancett B2800XP

Page 1: ...Flow Monitor B2800XP Explosion Proof Flow Monitor Advanced DSY PM 00279 EN 03 March 2017 User Manual...

Page 2: ...Mode 11 Additonal Scaling Parameters 12 Flow 4 mA Setting 12 Flow 20 mA Setting 12 4 20 mA Calibration 12 4 20 mA Test 12 Additional Input Options 13 Battery Replacement 13 Maintenance 14 Additional...

Page 3: ...serious personal injury Indicates a hazardous situation which if not avoided could result in severe personal injury or death Indicates a hazardous situation which if not avoided is estimated to be ca...

Page 4: ...lectable units viewing in run mode and prompts for variables in program mode The display can show rate total or alternate between both rate and total MENU ENTER Programming Buttons Figure 1 B2800XP fl...

Page 5: ...amage to the cover threads and glass lens when glass lens cover is used 5 Pull wires into enclosure making certain they are long enough to make the required connections and to remove the instrument or...

Page 6: ...b Size Kit Number Meter Sizes 1 2 in NPT Hub B280 742 3 8 in 1 2 in 3 4 in with 1 2 in NPT End Fittings 1 in NPT Hub B280 737 All Sizes with 1 in NPT End Fittings and Larger Installation Kit P N B280...

Page 7: ...ion turn on the lock out feature to prevent unauthorized access or changing the meter s setup parameters MENU ENTER Figure 3 Front panel Buttons MENU Enters and exits PROGRAM mode UP Scrolls forward t...

Page 8: ...If the current setting is correct press ENTER to advance to the next parameter To change the current setting press UP or RIGHT to scroll to the bore size of your meter Press ENTER to save and advance...

Page 9: ...rams were chosen as the RATE UNT or TOTL UNT the monitor advances to the SP GRAV parameter Specific Gravity At the SP GRAV parameter press ENTER The first digit of the current specific gravity flashes...

Page 10: ...plitude of the pulse is dependent on the voltage level of the supply connected to the pulse output and is limited to a maximum 30V DC Linearization Linearization enhances the accuracy of the display T...

Page 11: ...password and return to the METER parameter The reset pasword is now required to reset the totals on the monitor NOTE N Entering a password in the PASSWORD screen and leaving the default password in t...

Page 12: ...4 20 mA Calibration The 4 20 mA Calibration parameter is the fine adjustment of the 4 20 mA output The 4 mA setting is typically between 35 50 To set the 4 mA value connect an ammeter in series with...

Page 13: ...Power Figure 7 Circuit board layouts BATTERY REPLACEMENT Battery powered monitors use a single 1 5V D size alkaline battery When replacement is necessary use a clean fresh battery for continued troub...

Page 14: ...ates some form of alternating signal that can be raw that is no format amplification or wave shaping can be done prior to transmission to the readout The output pulse rate is related proportionally to...

Page 15: ...t 2 25 Pulse Output Signals for Non linear Processes Few flow meters actually behave in a linear way There is always some uncertainty about the exact flow at a given reported input value For many comm...

Page 16: ...nitor pig tail This should stop the noise If not then try reorientating the meter to a new location Flow rate indicator bounces This usually indicates a weak signal Replace pickup and or check all con...

Page 17: ...ity 30 mV p p Over Voltage Protected 30V DC Frequency Measurement Accuracy 0 1 Temperature Drift 50 ppm C maximum Optional Analog Output Loop Powered Version Type 4 20 mA current loop Resolution 1 400...

Page 18: ...RT NUMBER INFORMATION NOTE Advanced B2800 monitors only The default is gallons per minute Program Level A Advanced B 28 A X X X X Power Option B Battery L Loop Mounting Style X Explosion proof Units o...

Page 19: ...INTENTIONAL BLANK PAGE Page 19 March 2017 DSY PM 00279 EN 03...

Page 20: ...Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus Badger Meter Europe ul Korfantego 6 44 193 Knur...

Reviews: