Meter Type

At the 

METERTYP

 prompt, press 

ENTEO

  The current meter type displays  If the current selection is correct, press 

ENTEO

 

to advance to the next parameter  To change the type, press 

UP

 or 

OIGHT

  Press 

ENTEO

 to save and advance to the next 

parameter  If 

GAS

 is selected, the operating pressure (psig) and operating temperature (° F) must be entered  If 

LIQUID

 is 

selected, the monitor advances to the 

DAMPING

 parameter  

OTEE:

N

The 4…20 mA zero and span values are not factory set 

Operating Pressure

At the 

OP PRES

 prompt, press 

ENTEO

  The first digit of the current setting flashes  If the current setting is correct, press 

ENTEO

 to advance to the next paramter  To change the current setting, press 

OIGHT

 to move to the correct digit  Press 

UP

 to 

increment the digit until it matches the new operating pressure  Repeat for all digits  Press 

ENTEO

 to save and advance to the 

OP TEMP

 parameter 

Operating Temperature

At the 

OP TEMP

 prompt, press 

ENTEO

  The first digit of the current setting flashes  If the current setting is correct, press 

ENTEO

 to advance to the next paramter  To change the current setting, press 

OIGHT

 to move to the correct digit  Press 

UP

 to 

increment the digit until it reaches the new operating temperature  Repeat for all digits  Press 

ENTEO

 to save and advance to 

the 

DAMPING

 parameter 

Damping Factor

The damping factor is increased to enhance the stability of the flow readings, and decreased to allow the flow meter to react 

faster to changing values of flow  This parameter can be any value 0…99 with 0 being the default  
At the 

DAMPING

 prompt, press 

ENTEO

  The first digit of the current damping setting flashes  If the current selection is correct, 

press 

ENTEO

 to advance to the next parameter  To change the damping factor, press 

UP

 to increment the digit  Press 

OIGHT

 

to move to the next digit  After all digits are entered, press 

ENTEO

 to save and advance to the 

PULS OUT

 parameter 

Totalizer Pulse Output

The pulse output parameter can be either enabled or disabled  When enabled, this output generates a 20 mS duration pulse 

for every time the least significant digit of the totalizer increments  The amplitude of the pulse is dependent on the voltage 

level of the supply connected to the pulse output and is limited to a maximum 30V DC 

Linearization

Linearization enhances the accuracy of the display  The linearization accepts a maximum of ten points and requires additional 

calibration data from the meter being used with the monitor  Typically, calibration information can be obtained in three, 

five and ten points from the flow meter’s manufacturer  If linearization is not needed, press 

OIGHT

 to advance to the next 

parameter  To complete linearization, press 

ENTEO

 at the 

LINEAR

 prompt  The meter advances to the 

NUM PTS

 parameter 

Number of Points

If the number of points is set to 

0

, linearization is disabled  Press 

ENTEO.

 The most significant digit of the number of points 

entry begins to flash  The first number can be a 

1

 or a 

0

 only  Press 

UP

 

to increment the first digit  Press 

OIGHT

 

to move to the 

least significant digit  When both digits have been entered, press 

ENTEO

 to save and advance to the 

FREQ 1

 parameter 

Frequency

At the 

FREQ 1

 prompt, press 

ENTEO.

 The first digit of the first linear point’s frequency input flashes  If the first frequency is 

correct, press 

ENTEO

 to advance to the next parameter  To change the frequency, press 

UP

 to increment the digit  Press 

OIGHT

 to move to the next digit  After all digits are entered, press 

ENTEO

 to save and advance to the 

COEFF 1

 parameter  

Coefficient

The coefficient is the value applied to the nominal K-factor to correct it to the exact K-factor for that point  The coefficient is 

calculated by dividing the actual K-factor for that point by the average K-factor for the flow meter 

Coefficient = 

Average K-Factor

Actual K-Factor 

At the 

COEFF

 prompt, press 

ENTEO.

 The first digit of the coefficient flashes  If the first coefficient is correct, press 

ENTEO

 

to advance to the next parameter  To change the frequency, press 

UP

 to increment the digit  Press 

OIGHT

 to move to the 

next digit  Repeat for all digits  After all digits are entered, press 

ENTEO

 to save and advance to the next set of linear points  

Continue entering pairs of frequency and coefficient points until all data has been entered  Press 

MENU

 twice at the 

NUM PTS

 

prompt to exit to the 

LINEAR

 prompt  Press 

OIGHT

 to advance to the 

PASSWORD

 parameter 

Programming

Page 10 

March 2017 

DSY-PM-00279-EN-03

Summary of Contents for Blancett B2800XP

Page 1: ...Flow Monitor B2800XP Explosion Proof Flow Monitor Advanced DSY PM 00279 EN 03 March 2017 User Manual...

Page 2: ...Mode 11 Additonal Scaling Parameters 12 Flow 4 mA Setting 12 Flow 20 mA Setting 12 4 20 mA Calibration 12 4 20 mA Test 12 Additional Input Options 13 Battery Replacement 13 Maintenance 14 Additional...

Page 3: ...serious personal injury Indicates a hazardous situation which if not avoided could result in severe personal injury or death Indicates a hazardous situation which if not avoided is estimated to be ca...

Page 4: ...lectable units viewing in run mode and prompts for variables in program mode The display can show rate total or alternate between both rate and total MENU ENTER Programming Buttons Figure 1 B2800XP fl...

Page 5: ...amage to the cover threads and glass lens when glass lens cover is used 5 Pull wires into enclosure making certain they are long enough to make the required connections and to remove the instrument or...

Page 6: ...b Size Kit Number Meter Sizes 1 2 in NPT Hub B280 742 3 8 in 1 2 in 3 4 in with 1 2 in NPT End Fittings 1 in NPT Hub B280 737 All Sizes with 1 in NPT End Fittings and Larger Installation Kit P N B280...

Page 7: ...ion turn on the lock out feature to prevent unauthorized access or changing the meter s setup parameters MENU ENTER Figure 3 Front panel Buttons MENU Enters and exits PROGRAM mode UP Scrolls forward t...

Page 8: ...If the current setting is correct press ENTER to advance to the next parameter To change the current setting press UP or RIGHT to scroll to the bore size of your meter Press ENTER to save and advance...

Page 9: ...rams were chosen as the RATE UNT or TOTL UNT the monitor advances to the SP GRAV parameter Specific Gravity At the SP GRAV parameter press ENTER The first digit of the current specific gravity flashes...

Page 10: ...plitude of the pulse is dependent on the voltage level of the supply connected to the pulse output and is limited to a maximum 30V DC Linearization Linearization enhances the accuracy of the display T...

Page 11: ...password and return to the METER parameter The reset pasword is now required to reset the totals on the monitor NOTE N Entering a password in the PASSWORD screen and leaving the default password in t...

Page 12: ...4 20 mA Calibration The 4 20 mA Calibration parameter is the fine adjustment of the 4 20 mA output The 4 mA setting is typically between 35 50 To set the 4 mA value connect an ammeter in series with...

Page 13: ...Power Figure 7 Circuit board layouts BATTERY REPLACEMENT Battery powered monitors use a single 1 5V D size alkaline battery When replacement is necessary use a clean fresh battery for continued troub...

Page 14: ...ates some form of alternating signal that can be raw that is no format amplification or wave shaping can be done prior to transmission to the readout The output pulse rate is related proportionally to...

Page 15: ...t 2 25 Pulse Output Signals for Non linear Processes Few flow meters actually behave in a linear way There is always some uncertainty about the exact flow at a given reported input value For many comm...

Page 16: ...nitor pig tail This should stop the noise If not then try reorientating the meter to a new location Flow rate indicator bounces This usually indicates a weak signal Replace pickup and or check all con...

Page 17: ...ity 30 mV p p Over Voltage Protected 30V DC Frequency Measurement Accuracy 0 1 Temperature Drift 50 ppm C maximum Optional Analog Output Loop Powered Version Type 4 20 mA current loop Resolution 1 400...

Page 18: ...RT NUMBER INFORMATION NOTE Advanced B2800 monitors only The default is gallons per minute Program Level A Advanced B 28 A X X X X Power Option B Battery L Loop Mounting Style X Explosion proof Units o...

Page 19: ...INTENTIONAL BLANK PAGE Page 19 March 2017 DSY PM 00279 EN 03...

Page 20: ...Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus Badger Meter Europe ul Korfantego 6 44 193 Knur...

Reviews: