Data management
Page 14/23
MID_M2000_BA_02_PB_1612
Meter calibration category
Absolute
index
Relative
index
Write
access level
Index name
ModBus
®
register
address
Data type
Static
revision
149 39
READ-ONLY
Detector
diameter
0x006F
UINT16 —
150 40
READ-ONLY
Detector
diameter
other [mm]
0x0070 UINT16
—
151 41
READ-ONLY
Detector
factor
0x0071
FLOAT32 —
152
42
READ-ONLY
Detector offset [m/s]
0x0075
FLOAT32
—
153 43
READ-ONLY
Amplifier
factor
0x0079
FLOAT32 —
154 44
READ-ONLY
Detector
current
[A]
0x007D
FLOAT32 —
155 45
SERVICE Power
line
Frequency [Hz]
0x0081 UINT16 YES
156 46 ADMIN
Excitation
frequency
[Hz]
0x0082 UINT16 YES
157
47
SERVICE
Scale factor [%]
0x010B
FLOAT32
YES
Meter measurement settings category
Digital input category
Absolute
index
Relative
index
Write
access level
Index name
ModBus
®
register
address
Data type
Static
revision
158 48 USER
Flow
unit
0x0083
UINT16 YES
159 49 USER
Volume
unit
0x0084
UINT16 YES
160 50 USER Unit
multiplier
0x0085
UINT16 YES
161
51
USER
Full scale velocity
[m/s]
0x0086
FLOAT32 YES
240 130 USER Full
scale
flow [User
Units]
0x0090
FLOAT32 YES
162
52
USER
Low flow cutoff [%]
0x008E
FLOAT32
YES
163 53 USER Flow
direction
0x0092
UINT16 YES
164 54 USER Damping
factor [s]
0x0093
UINT16
YES
Absolute
index
Relative
index
Write
access level
Index name
ModBus
®
register
address
Data type
Static
revision
165
55
SERVICE
Digital input: nput
operation
0x0094
UINT16 YES
166
56
READ-ONLY
Digital input: status
0x0155
UINT16
—