Digital air- conditioner controller KR- 454
You can select the outputs
1
...
16
with this test program. The number is displayed on the
right on the display. You quit the test program by pressing key
S6
( AUTO ).
By pressing key
S14
“time“ you can switch the outputs on and off.
Assignment of the outputs:
output 1:
front box 40%
output 2:
front box 100%
output 3:
auxiliary water pump roof duct upper deck
output 4:
auxiliary water pump roof duct upper or lower deck
output 5:
auxiliary water pump roof duct lower deck
output 6:
roof duct fan
output 7:
compressor clutch
output 8:
air-conditioning 100%
output 9:
circulating air flap
output 10:
stationary heating (Webasto)
output 11:
water pump
output 12:
frost warning
output 13:
reserve
output 14:
reserve
output 15:
convector valve open upper deck
output 16:
convector valve close upper deck
PROGRAM 8:
This program tests the valve- and servo motor outputs I/1...8 .
You will see "
v1
" on the left on the display. You can select the
outputs 1...8 with keys
S12
and
S13.
The number is displayed on
the right. You quit the test program by pressing key
S6
( AUTO ).
Assignment of the outputs:
output 1:
circulating air driver's cockpit open
output 2:
circulating air driver's cockpit close
output 3:
screen defrost open
output 4:
screen defrost close
output 5:
driver/centre aisle open
output 6:
driver/centre aisle close
output 7:
front box valve driver's cockpit close
output 8:
front box valve driver's cockpit open
PROGRAM 9:
This program tests the valve outputs II/1...8 .
INDUSTRIE-ELEKTRONIK
Control and regulating systems for vehicle air conditioning
D-71691 Freiberg a.N.,
Siemensstr.21
Phone: +49 7141 / 68877 - 0
Fax: +49 7141 / 68877 - 39
page: 26
of:
42
04541530.SDW
Issue: October 1998 - Copyright (C) BADER GmbH - Alterations reserve