Digital air- conditioner controller KR- 454
Error
6
Discontinuity, -"-
Error
7
Short circuit, roof duct sensor lower deck
Error
8
Discontinuity, -"-
Error
9
Short circuit, convector sensor, front lower deck
Error
10
Discontinuity, -"-
Error
11
Short circuit, convector sensor, rear lower deck
Error
12
Discontinuity, -"-
Error
13
Short circuit, passenger compartment sensor upper deck
Error
14
Discontinuity, -"-
Error
15
Short circuit, roof duct sensor upper deck
Error
16
Discontinuity, -"-
Error
17
Short circuit, convector sensor, front upper deck
Error
18
Discontinuity, -"-
Error
19
Short circuit, convector sensor, rear upper deck
Error
20
Discontinuity, -"-
Error
21
Short circuit front box sensor driver's cockpit (option)
Error
22
Discontinuity -“-
Error
23
Short circuit front box sensor upper deck (option)
Error
24
Discontinuity -“-
Error messages: Input/output errors
Error
33
No air-conditioner compressor check-back signal
Error
34
No auxiliary heating system (WEBASTO) check-back signal
Error
35
Prop valve roof duct lower deck potentiometer defective
Error
36
Prop valve driver's cockpit potentiometer defective
Error
37
Prop valve convector lower deck potentiometer defective
Error
39
Prop valve roof duct upper deck potentiometer defective
Error
40
Prop valve front box upper deck potentiometer defective
Error
41
Prop valve convector upper deck potentiometer defective
Error
42
Prop valve front box upper deck potentiometer defective
Error
43
Setpoint potentiometer front box upper deck, discontinuity
Error messages: voltage errors
Error
80
No valve potentiometer voltage (+5V)
Error
81
Outputs valve motors or servo motors of front box overloaded
Error
82
Valve assignment (valve-potentiometer) error
Error
84
Outputs overloaded (total current)
INDUSTRIE-ELEKTRONIK
Control and regulating systems for vehicle air conditioning
D-71691 Freiberg a.N.,
Siemensstr.21
Phone: +49 7141 / 68877 - 0
Fax: +49 7141 / 68877 - 39
page: 16
of:
42
04541530.SDW
Issue: October 1998 - Copyright (C) BADER GmbH - Alterations reserve