10
V1.05 Revised 03/16/2021
Control
-
Saw motor is not turning on
o
Try resetting the machine with the Reset Push Button on the Panel
o
Enable the Web Access for the PLC200 as shown in the MiterX Service Manual
o
Check for Input/Output issues in the
“InputOutput_Status” and
“SawVFD_
Cyclic
Status”
watch tables
o
If the issue is still unknown,
check for the fault code in the “SawVFD_FaultCode”
watch table and contact BACA
-
Carriage motor is not turning right or left
o
Try resetting the machine with the Reset Push Button on the Panel
o
Check the conditions of the Left and
Right Limit Sensors and make sure they’re
intact and free from dust
o
Enable the Web Access for the PLC200 as shown in the MiterX Service Manual
o
Check for Input/Output issues in the “InputOutput_Status” and
“CarriageVFD_CyclicStatus” watch tables
o
If the issue is still unknown,
check for the fault code in the “CarriageVFD_FaultCode”
watch table and contact BACA