![BabyOno 790 Manual Download Page 5](http://html1.mh-extra.com/html/babyono/790/790_manual_3053022005.webp)
5
6.Over temperature prompt function
Under the body temperature mode, if the measured body temperature is
higher than or equal to 38.0°C, the product will be vibrated for three times.
7.Changing the batteries
Display: when the LED screen displays the flashed symbol , the battery needs to change. Operation: Open the lid and change the batteries, taking great care with
the correct positioning. A mistake with this could cause damage to the apparatus and compromise the guarantee of your JXB-311. Never use rechargeable batteries.
Use only batteries for single usage.
X. Technical specifications
1.Normal using condition
Ambient temperature: 10°C ~ 40°C (50°F ~ 104°F)
Relative humidity: ≤ 85%
Pressure altitude: 700 hPa to 1060 hPa
2.Storage and shipping condition
Ambient temperature: -20°C ~ 55°C (-4°F ~ 131°F)
Relative humidity: ≤ 95%
3.Batteries: DC 3V (2 pcs AAA batteries)
4.Unit size: 154 x 40 x 31 mm (L x W x H)
5.Unit weight (without battery): 64g
6.Temperature display resolution: 0.1°F (0.1°C)
7.Measuring range:
In body mode: 32°C ~ 43°C (89.6°F ~ 109.4°F)
In surface temp mode: 0°C ~ 60°C (32°F ~ 140°F)
In room mode: 0°C ~ 40°C (32°F ~ 104°F)
8.Precision:
32.0°C ~ 34.9°C (89.6°F ~ 94.8°F) ±0.3°C(±0.6°F)
35.0°C ~ 42.0°C (95.0°F ~ 107.6°F) ±0.2°C(±0.4°F)
42.1°C ~ 43.0°C (107.8°F ~ 109.4°F) ±0.3°C(±0.6°F)
9.Consumption: ≤300mW
10.Accuracy: ±0.6°F (0.3°C)
11.Measuring distance: ≤3cm (1.2in)
12.Automatic power-off: <30 secs
13.Memory: 32 sets
14. Measuring position: Forehead skin
Note: The Non-contact Infrared Thermometer Model JXB-311 can take temperature readings below 32°C or above 43.0°C (89.6°F to 109.4°F) but precision is not guaranteed
outside of this range. Longevity of the product. The JXB-311 was conceived for an intense and professional use, its longevity is guaranteed for 100,000 takings.
XI. Maintenance of the product
- The protective glass over the lens is the most important and fragile part of the thermometer, please take great care of it.
- Clean the glass with cotton fabric, wet with 95° alcohol.
- Do not use other batteries than mentioned batteries, do not recharge non rechargeable batteries, do not throw in fire.
- Remove the batteries when thermometer is not used for an extended period of time.
- Do not expose the thermometer to sunlight or water.
- An impact will damage the product.
XII. Accessories
User Manual in English 1 pc
AAA alkaline batteries 2 pcs
XIII. Guidelines
This device complies with the EU Directive 93/42/EEC concerning medical products the ISO 80601-2-56 and the European Standard EN60601-1-2 and is subject to
particular precautions with regard to electromagnetic compatibility.
XIV. Troubleshooting
If you have problems while using your thermometer, please refer to this guide to help resolve the problem. If the problem persists, please contact our customer service.
THE SCREEN DISPLAYS TEMPERATURE HIGHER THAN 43.0°C (109.4°F):
The temperature is in Fahrenheit. Change the measurement to Celsius.
THE SCREEN DISPLAYS TEMPERATURE LOWER THAN 32°C (89.6°F):
To take the surface temperature, press the “BODY” button and set to the reading called “Body” , If the device is in Surface Temp Mode, the 32°C
(89.6°F) temperature displayed is showing the external temperature of your body, rather than the internal.
THE SCREEN DISPLAYS THE MESSAGE HI
When using the JXB-311 Thermometer, the message “HI” can show on the screen. In this case,the temperature is above the measurement range selected, either above
43.0 °C (109.4°F) in Body Mode.