CO
2
Control
The PPM-UP mode, Fuzzy Logic mode and manual shutdown mode are available on the device.
By analyzing the CO
2
data read by the sensor, the relative CO
2
concentration in the environment can
be controlled and adjusted. The CO
2
control mode is composed of a generator [PPM UP] mode and
TANK [Fuzzy-Logic] mode. When the CO
2
concentration is lower than the start value, it will start the
output of the relevant devices (AC24V output and AC Station module); If it is higher than the end
value, it will stop the output of the relevant devices.
When the CO
2
concentration in the environment reaches the corresponding range, the output action
of the corresponding equipment will be stopped to achieve the goal of controlling CO
2
concentration
in the environment.
Humidity control
The device can be set to humidify mode, dehumidify mode, synchronous humidify and dehumidify
control mode and idle mode.
After analysis of the humidity data read by the sensor, the humidity in the environment can be
controlled and adjusted. The humidity is controlled within a range. That is, when the humidity is below
the humidification value, the humidifier (AC24V output) will be started, and when it is above the initial
value, the dehumidifier (AC24V output) will be started.
After the humidity of the environment is within the corresponding range, the output of the correspond-
ing device is stopped to control the humidity in the environment.
Temperature control
The heating mode, cooling mode, synchronous heating, and cooling mode and idle mode.
After analysis of the temperature data read by the sensor, the ambient temperature can be controlled
and adjusted. The temperature can be controlled within a range. When the temperature is below the
heating value, the heater (AC24V output) will be started; when it is above the initial value, the cooler
(AC24V output) will be started.
High PPM Protection
CO
2
Target
value
Activate
Value
(Fuzzy Logic
/PPM UP)
Deadband
Low Humi
protection value
High Humi
protection value
Humidification
on value
Dehumidification
on value
Adaption
range
Deadband
Deadband
12