background image

CO

2

 Control

The PPM-UP mode, Fuzzy Logic mode and manual shutdown mode are available on the device.

By analyzing the CO

2

 data read by the sensor, the relative CO

2

 concentration in the environment can 

be controlled and adjusted. The CO

2

 control mode is composed of a generator [PPM UP] mode and 

TANK [Fuzzy-Logic] mode. When the CO

2

 concentration is lower than the start value, it will start the 

output of the relevant devices (AC24V output and AC Station module); If it is higher than the end 
value, it will stop the output of the relevant devices. 

When the CO

2

 concentration in the environment reaches the corresponding range, the output action 

of the corresponding equipment will be stopped to achieve the goal of controlling CO

2

 concentration 

in the environment.

Humidity control

The device can be set to humidify mode, dehumidify mode, synchronous humidify and dehumidify 
control mode and idle mode.

After analysis of the humidity data read by the sensor, the humidity in the environment can be 
controlled and adjusted. The humidity is controlled within a range. That is, when the humidity is below 
the humidification value, the humidifier (AC24V output) will be started, and when it is above the initial 
value, the dehumidifier (AC24V output) will be started.

After the humidity of the environment is within the corresponding range, the output of the correspond-
ing device is stopped to control the humidity in the environment.

Temperature control

The heating mode, cooling mode, synchronous heating, and cooling mode and idle mode.
After analysis of the temperature data read by the sensor, the ambient temperature can be controlled 
and adjusted. The temperature can be controlled within a range. When the temperature is below the 
heating value, the heater (AC24V output) will be started; when it is above the initial value, the cooler 
(AC24V output) will be started.

High PPM Protection

CO

2

Target 

value

Activate 

Value

(Fuzzy Logic

/PPM UP)

Deadband

Low Humi

protection value

High Humi

protection value

Humidification 

on value

Dehumidification 

on value

Adaption 

range

Deadband

Deadband

12

Summary of Contents for Hydro-Pro

Page 1: ...Hydro Pro Environmental Control System www babala hydroponics cn www pro leaf com Instruction Manual...

Page 2: ...V Overview of Hydro Pro System Specifications of Hydro Pro Series Products Warings Cautions Avertissement Pr cautions Installation Instructions Installation Diagram VI VII Operation Instructions 1 In...

Page 3: ...Hydro Pro allows you to select the type of light LED or HID to be controlled and can simultaneously employ 2 channels of independent or interlocked light control logic in different modes to create mu...

Page 4: ...utput ports RJ12 RJ12 x 4 4 channel RS485 communication Signal line output DC24V 1 0A Network port RJ45 Dimensions 14 H x 17 W x 4 D excluding length of power cable Power cord length 2m 6 5ft Net weig...

Page 5: ...ty accuracy 2 RH Temperature range 0 70 Temperature accuracy 0 5 Maximum quantity 4pcs per unit Communication mode RS485 Modbus RTU Light Sensor Photocell Main parameters Default values Working voltag...

Page 6: ...er 1100W Communication terminal RJ12 connector Indicator Green LED Maximum connections quantity 32pcs Communication Mode RS485 Modbus RTU Main parameters Default values Input Voltage DC24V Output Volt...

Page 7: ...cket is consistent with the parameter described Pr cautions Avant d ins rer le Contr leur principal Hydro pro v rifiez que la tension de la prise correspond aux param tres d crits Cautions After the e...

Page 8: ...e controller and connect the corresponding devices accordingly Heat Cool Humidify Humidify Dehumidify 01 02 03 04 05 06 07 08 09 10 Dehumidify Light 1 Light 2 Alarm Alarm 2 Loosen the screw on the con...

Page 9: ...onnected to the probe socket on the bottom of the Hydro Pro Master Controller and check if the connector is properly inserted Place the probe of the light sensor in the place to be measured with its f...

Page 10: ...V Installation Diagram 4x CO2 Sensor Lights Lights Net Power AC 110V USB TF Reset 4x Humidity Temp Sensor CO2 Tank CO2 Generator Fan Devices Devices Distribution box Dehumidifier 9...

Page 11: ...box or related equipment that supports AC24V signals 6 Before the connection it is necessary to check if the positive and negative poles of the output line are correct After the circuit connection is...

Page 12: ...related devices are displayed on the interface including VPD humidity temperature CO2 light day and night 10 49 05 11 01 2020 DaytimeMode LIGHT ON at 08 00 OUTPUT MAX 80 OFF at 18 00 Type LED HUMI CLI...

Page 13: ...ad by the sensor the humidity in the environment can be controlled and adjusted The humidity is controlled within a range That is when the humidity is below the humidification value the humidifier AC2...

Page 14: ...be used immediately out of the box The Hydro Pro controller will display the date symbol in the upper left corner of the day night mode Day mode control The Hydro Pro controller outputs signals to the...

Page 15: ...uding VPD humidity temperature CO2 light day and night The day and night status is displayed in the upper left corner of the interface and the current time and date are displayed in the top middle pos...

Page 16: ...n navigate to other related interfaces via the interface on the right side Time format Set the date format as MM DD YYYY and the time format as HH MM SS 12 24 hour time format 12 hour and 24 hour time...

Page 17: ...D connection status online offline will be displayed simultaneously In this interface you can choose to find unregistered devices 2 2 Adding sensors or devices In this interface you can delete or find...

Page 18: ...evice list The RS485 port for the sensor is the Sensor port The RS485 port for the device is the Device port The RS485 port for the LDA 1 device is the Light LINE 1 or Light LINE 2 port 2 3 Deleting s...

Page 19: ...ower left corner the temperature value heating on value cooling on value and the corresponding Deadband value are displayed In the upper right corner the target value of CO2 Deadband value and high CO...

Page 20: ...TEM SETTING CONNECTION STATUS 5 CO2 Setting In the CO2 setting interface the real time data of the currently connected sensor are displayed as well as the device s CO2 parameters set such as working m...

Page 21: ...which a dialogue box will pop up prompting you to save the data the data modified will not take effect unless they are saved 5 2 Default parameters 5 3 Day and night setting The device will not start...

Page 22: ...ce will display the specific working status of the device In different modes different icons are used to display the current working status 5 6 Interlock settings When performing actions the working s...

Page 23: ...umidity protec tion value target value and deadband value After the data are set the Save button will light up At this time press the Save button to save the data after which a dialogue box will pop u...

Page 24: ...idify mode the device will turn on the dehumidification output port when the current value is higher than Dehumidify value and immediately turn off the dehumidification output port when the humidity v...

Page 25: ...vice are displayed in the upper part of the device If the device is not equipped with a temperature and humidity module the relevant temperature and humidity data of the 3 in 1 module will be used Mea...

Page 26: ...fication High Temp Protection value The value set needs to be higher than the Cool target value of heating After the data are set the Save button will light up At this time press the Save button to sa...

Page 27: ...heating output port when the real time tempera ture value is higher than Heat Deadband value The device will turn on the dehumidification output port when the current value is higher than Cool value...

Page 28: ...ool 15 0 Deadband IRRIGATION STATUS Auto 08 30 60 18 30 HID FOLLOW MODE CO2 PPM 1100 Deadband 200 Target 1200 High CO2 PPM Protection 5000 SYSTEM SETTING CONNECTION STATUS 8 Light Setting On the home...

Page 29: ...or the response is enabled again which is from 3min to 180min 8 4 Sun r s parameter setting In the interface the Sun R S mode can be enabled and disabled as appropriate that is a fixed off time can be...

Page 30: ...minimum light intensity of 10 and a maximum light intensity of 115 LIGHT MODE LED HID ON Time at 8 00 HID Delay 3min 180min Sun R S 0 60min following the main line setting OFF TEMP 10 0 70 Output Max...

Reviews: