![babala Hydro-Pro Instruction Manual Download Page 11](http://html1.mh-extra.com/html/babala/hydro-pro/hydro-pro_instruction-manual_3155174011.webp)
Connection Guide
Note:
Before installing the equipment, the user needs to consider the number of sensors and related
devices that need to be equipped based on the actual conditions of the planting area, for the heavy
current (110V-380V) devices in the circuits should be installed in the distribution box first.
1. Connect the sensor module to the Sensor port in series.
2. Connect the AC Station socket module to the Device port in series.
3. Connect the LDA-1 light control module to the LINE-1 port, which is the main light control line.
4. Connect the LDA-1 light control module to the LINE-2 port, which represents the auxiliary
light control line.
5. Connect the internal 10-channel port to the corresponding configuration in the distribution box
or related equipment that supports AC24V signals.
6. Before the connection, it is necessary to check if the positive and negative poles of the output
line are correct.
After the circuit connection is completed, plug in the power and turn on the device.
10
Basic configuration in the standard working environment with a grow area of 200m
3
Equipment
Quantity
Purpose
Hydro-Pro Master Controller
1
Master Controller
CO
2
four-in-one sensor
1
Monitoring CO
2
parameters (Relative CO
2
concentration value), relative temperature value,
relative humidity value, and light parameters
Temperature, Humidity and Light
three-in-one Sensor
1
Monitoring the relative temperature value,
relative humidity value, and light parameters
AC Station Module
1
Used to control the CO
2
output device (TANK or
generator)
LDA-1 Light Control Module
2
Used to control the CO
2
output device (TANK
or generator)
RS485 Cable
Several
Extension lines for connecting each terminal