background image

8

Manual: OMS-Nano Remote-Switch for 10Micron Mounts

Under 

Relays-No. 2

 the second relay (labelled "I/O Switch" on the OMS-Nano) can 

be freely programmed for future applications. 

If you already want to use the second relais now, we can provide the documentation, 

if you contact us at [email protected]. Please note that the warranty is 
void once the housing is opened or the second port is reprogrammed. These altera-
ions are done at your own risk.

Completion of the work

After each change of the settings, the switch box must be switched off and on again to 
successfully complete the programming. After changing the IP address and a restart, 
the OMS-Nano can be reached under the new IP address. Please remember to make 
the necessary changes to the bookmarks as well.

Likewise, the IP-4 details in the network settings can be reset to the original values if 

necessary.

BAADER PLANETARIUM

Zur Sternwarte 4 • D-82291 Mammendorf • Tel. +49 (0) 8145 / 8089-0 • Fax +49 (0) 8145 / 8089-105

www.baader-planetarium.com  • [email protected] • www.celestron.de

G

M

B

H

© Baader Planetarium GmbH. All Rights reserved. Products or instructions may change without notice or obligation. 
Images and illustrations may differ from the original products. We reserve the right of errors. Reproduction of this 
instruction manual, complete or in parts, only with written permission by

www.

baader-planetarium

.com

Summary of Contents for OMS-Nano

Page 1: ...from remote To ensure optimal performance please read this instruction manual before using the OMS Nano we recommend that you study this manual before installing and using it EN ver 01 2022 BAADER PLA...

Page 2: ...pe of Delivery Contents Scope of Delivery 2 Mode of Operation 3 Connecting the Switch 3 Network Settings 4 Control of the Switch 6 Configuration 6 Completion of the Work 8 2 1 3 4 1 OMS Nano switch 2...

Page 3: ...n off This can take up to 30s Disconnect the mount from the power supply pull the plug Plug the jack plug of the switch module into the jack socket EXT SWITCH 1 of the control box Connect the supplied...

Page 4: ...Switch for 10Micron Mounts Network Settings Open network and internet settings on your computer on the example of Windows 10 Go to Ethernet Settings Choose Change adapter options Right click on Ethern...

Page 5: ...coll Version 4 and click on Properties Enter the following IP data Your computer must be in the range 192 168 0 0 to 192 168 0 255 the IP adress 192 168 0 123 is occupied by the OMS Nano To finish thi...

Page 6: ...irtual Keypad displays the connection data Remember to move the mount to its designated park position before switching it off Switching off the mount Click the button 10 Micron Pulse again The mount i...

Page 7: ...ings have not yet been transmitted to the switch box the Update Pen ding button lights up red In this case wait until the button button turns grey again Under the menu item Relays all necessary settin...

Page 8: ...e programming After changing the IP address and a restart the OMS Nano can be reached under the new IP address Please remember to make the necessary changes to the bookmarks as well Likewise the IP 4...