Manual: OMS-Nano Remote-Switch for 10Micron Mounts
Control of the Switch
Open a web browser and enter the assigned IP-address:
192.168.0.123/index.htm
The web interface opens. This address can be defined
in the web browser as a bookmark or start page, so that
the switch module can be found automatically the next
time the browser is called up.
Switch on the mount:
Click on
10 Micron Pulse.
The mount now starts up, which is indicated in the keypad display by showing
Con-
necting…
, if it was previously defined that the Virtual Keypad should connect via Auto
Connect after the mount has been started.
As soon as the mount has booted, the Virtual Keypad displays the connection data.
Remember to move the mount to its designated park position before switching it off.
Switching off the mount:
Click the button
10 Micron Pulse
again.
The mount is now shutting down.
Attention:
Prior to restarting, the mount must be completely shut down. The red LED
of the control box must have been extinguished. Since this is not visible in remote
mode, you should wait at least 30 seconds before operating
10 Micron Pulse
again.
Configuration
This function requires a USB connection to the switch box. This is used to secure access.
Open a web browser and enter the following IP address:
192.168.0.123/config.htm
The configuration web interface opens. This address can also be saved as a book-
mark in the web browser, so that the next time the browser is opened, the switching
module is easier to find.