8 Glossary and Abbreviations
52
DHV0075 b2 EN
©
b2 electronic
gmbh
8
Glossary and Abbreviations
The following explains abbreviations and selected terms used in this document
in alphabetical order.
Term
Explanation
Arc
Self-maintained gas conduction for which most of the charge carriers are
electrons supplied by primary
‑
electron emission (source: IEC)
Auto Adjust
Frequency
“0.1 Hz/Auto”
Mode that maximizes output frequency to highest allowable value
•
Greatest allowable frequency depends on the test load and test voltage
applied
•
For loads greater than nominal load, the instrument automatically reduces
the frequency
DUT
Device under Test
Duty (continuous)
Load state in which the unit operates for a long period.
Continuous means: no limitation in operating time based on temperature limits
Fault
An unplanned occurrence or defect in an item which may result in one or more
failures of the item itself or of other associated equipment (source: IEC)
Frequency[Hz]
Number of cycles per unit of time ; f=1/ Period (Time), units=Hz
1 Hz = 1cycle / 1 second
0.1 Hz = 1cycle / 10 second , etc.
Hipot
High potential (voltage)
HV
High Voltage: Voltage levels used in power distribution:
•
Medium Voltage: up to 36 kV
•
High Voltage: up to 110 kV
•
Extremely High Voltage: 220 kV, 380 kV or higher
(according to IEC/International Electrotechnical Vacabulary)
IEC
International Electrotechnical Commission
Peak value
Maximum Voltage = V
max
RMS value
Root Mean Square voltage
•
V
rms
= V
peak
/
√
2
for Sinusoidal wave forms
To Short
Forcing the electric potential differences between two or more conductive
parts to be equal to or close to zero
(Infinite current flows in a short circuit)
To Trip
Opening the circuit
(no current flows in open circuit)
VLF
Very Low Frequency
•
Typically between 0.01 -0.1 Hz
Vpeak
Vrms
V
time