  •  Diff erent patients should use individual clean medical cups and mouth pieces to  avoid 

cross infection.

  •  Some medicine dose not nebulizes well, please consult with your doctor.
  •  This appliance has a low-battery indicator. When the indicator light is green, the power 

is good for working. When the power light turns to orange, the battery is become 
weak, but you still can use product, however you may need to replace battery soon. If 
the power light is turns red it means voltage is too low to operate, please replace the 
battery immediately. 

  •  During using this appliance, if any irregularity or discomfort is observed, please discon-

tinue use this appliance.

  •  This product has built-in a 20-minute shutoff  timer. If it cannot be shutoff  automati-

cally, discontinue using and consult your dealer for help.

  •  If product detects no medicine in the medical cup, the LED indicator will turn red and 

fl ash three times then shutoff  automatically

  •  When under using, you can use the product in any angles. But, make sure medicine has 

good contact with mesh.

3. After using

  •  Please clean all parts after each usage and do follow instruction in the manual.
  •  Do not immerse this appliance in water when cleaning to avoid damaging any electri-

cal parts.

  •  Do not store this appliance in direct sunlight, outside our suggestion storage tempera-

ture and humidity environment.

  •  Keep this product from the reach of children. 

Summary of Contents for TH-134

Page 1: ...MESH NEBULIZER MODEL TH 134 MODEL TH 135 I n s t r u c t i o n s f o r u s e M E S H N E B U L I Z E R M O D E L T H 1 3 4 T H 1 3 5 READTHIS INSTRUCTION MANUAL CAREFULLY BEFORE USE...

Page 2: ...4 2 Intended purpose Page 4 3 Precautions Page 4 4 Notice for safety operation Page 6 5 Name of component Page 8 6 How to use Page 9 7 Clean and maintenance notice Page 10 8 Disinfection Page 11 9 Tro...

Page 3: ...nder the guidance of quali ed medical experts Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s o ce in a room of general household and in open ai...

Page 4: ...e raised to 40 C the product shelf temperature will raise up to 50 C 15 Do not use nebulizer on top of or close to other electronic device 16 Do not drop the nebulizer Do not apply strong shocks to th...

Page 5: ...such as very weak spray volume etc before using please replace it When this appliance has not been used for a while if any part such as medical cup mouth piece or mask seems dirty please proceed with...

Page 6: ...ny irregularity or discomfort is observed please discon tinue use this appliance This product has built in a 20 minute shuto timer If it cannot be shuto automati cally discontinue using and consult yo...

Page 7: ...rn red and ash three times before turn o automatically However the no medication detector has the possibility not function if that mesh blocked by medication 3 Medical Cup Contain the medicine Suggest...

Page 8: ...ailure to do so could result in damage due to battery leakage 2 Discard the waste batteries according to local law 3 Open the medical cup cover and pour the medicine into the medical cup and close the...

Page 9: ...ur in some hot water and close the cover completely Press the power button and operate 1 2 minutes to discard all remaining medicine completely Ensure medicine be cleaned completely after each using o...

Page 10: ...indicator light is on the battery power is too low Please replace the battery immediately 2 Discard the waste batteries according to local law 3 Check the battery is installed correctly Open battery c...

Page 11: ...ncorrect functioning of the nebulizer and can generate unsafe situations In order to prevent such unsafe situations your nebulizer is designed and tested according to EN60601 1 2 standards These stand...

Page 12: ...battery indication 2 0V 2 2V orange light Low battery indication 2 0V red light Operation environment 10 40 C 30 80 RH Storage Transportationenvironment 20 70 C 85 RH Nebulization rate 0 2mL min 1 0mL...

Page 13: ...12 SYMBOL INFORMATION symbol referent Read instructions before use Manufacturer s Name Article number Serial number Class II Equipment Type BF equipment Disposal for separate collection CE mark Prote...

Page 14: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland ISO9001 ISO13485 Certi ed This device complies with European Council Directive 93 42 EEC on Medical Devices...

Page 15: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland IM_TH 134_TH 135_ISO_2616...