3.   Use this appliance only for its intended use as described in this manual. 
4.   Do not use cotton swabs or other objects to touch the mesh; otherwise, product will 

not operate.

5.   Do not use diff erent type batteries in the same time. 
6.   Do not carry or store the product which is still remaining medicine in medical cup.   
7.   For the type, dose, and regimen of the medication, be sure to follow the instructions of 

a doctor.

8.   Do not immerse them in water. 
9.   Do not use disinfection solution containing sodium hypochlorite.
10.  Do not inhale by using water in the medication bottle.
11.  Do not drop or apply strong shock to the Main unit.
12.  Do not use any attachments or accessories not recommended by the manufacturer.
13. Discard the waste batteries and device according to local law.
14. When environment temperature raised to 40ºC the product shelf temperature will raise 

up to 50ºC.

15. Do not use nebulizer on top of or close to other electronic device. 
16. Do not drop the nebulizer. Do not apply strong shocks to the nebulizer.

FEATURE:

1.   This product utilizes ultrasonic vibration to turn liquid drug into fi ne mist which is then 

sent to the respiratory tract and oral cavity by a venting system so that therapeutic 
result can be achieved.

2.   Compact and easily to carry.
3.   Ultrasonic vibration which produces 100,000 ~120,000 vibrations per second.
4.   After 20-minutes continuously operation or when the medical cup is no medicine, 

the appliance will automatic shutdown. However, the no-medication detector has the 
possibility not function if that mesh blocked by medication.

5.   Built-in low-battery indicator.
6.   No matter use the product in diff erent angle, that still can operate normally in short term. 
When put the product upside down, medicine cannot contact to mesh, the product still can 
operate normally in few seconds (it can be diff erent if diff erent medicine is in using).  

Summary of Contents for TH-134

Page 1: ...MESH NEBULIZER MODEL TH 134 MODEL TH 135 I n s t r u c t i o n s f o r u s e M E S H N E B U L I Z E R M O D E L T H 1 3 4 T H 1 3 5 READTHIS INSTRUCTION MANUAL CAREFULLY BEFORE USE...

Page 2: ...4 2 Intended purpose Page 4 3 Precautions Page 4 4 Notice for safety operation Page 6 5 Name of component Page 8 6 How to use Page 9 7 Clean and maintenance notice Page 10 8 Disinfection Page 11 9 Tro...

Page 3: ...nder the guidance of quali ed medical experts Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s o ce in a room of general household and in open ai...

Page 4: ...e raised to 40 C the product shelf temperature will raise up to 50 C 15 Do not use nebulizer on top of or close to other electronic device 16 Do not drop the nebulizer Do not apply strong shocks to th...

Page 5: ...such as very weak spray volume etc before using please replace it When this appliance has not been used for a while if any part such as medical cup mouth piece or mask seems dirty please proceed with...

Page 6: ...ny irregularity or discomfort is observed please discon tinue use this appliance This product has built in a 20 minute shuto timer If it cannot be shuto automati cally discontinue using and consult yo...

Page 7: ...rn red and ash three times before turn o automatically However the no medication detector has the possibility not function if that mesh blocked by medication 3 Medical Cup Contain the medicine Suggest...

Page 8: ...ailure to do so could result in damage due to battery leakage 2 Discard the waste batteries according to local law 3 Open the medical cup cover and pour the medicine into the medical cup and close the...

Page 9: ...ur in some hot water and close the cover completely Press the power button and operate 1 2 minutes to discard all remaining medicine completely Ensure medicine be cleaned completely after each using o...

Page 10: ...indicator light is on the battery power is too low Please replace the battery immediately 2 Discard the waste batteries according to local law 3 Check the battery is installed correctly Open battery c...

Page 11: ...ncorrect functioning of the nebulizer and can generate unsafe situations In order to prevent such unsafe situations your nebulizer is designed and tested according to EN60601 1 2 standards These stand...

Page 12: ...battery indication 2 0V 2 2V orange light Low battery indication 2 0V red light Operation environment 10 40 C 30 80 RH Storage Transportationenvironment 20 70 C 85 RH Nebulization rate 0 2mL min 1 0mL...

Page 13: ...12 SYMBOL INFORMATION symbol referent Read instructions before use Manufacturer s Name Article number Serial number Class II Equipment Type BF equipment Disposal for separate collection CE mark Prote...

Page 14: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland ISO9001 ISO13485 Certi ed This device complies with European Council Directive 93 42 EEC on Medical Devices...

Page 15: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland IM_TH 134_TH 135_ISO_2616...

Reviews: