background image

Product Name

 

Respiratory Face Mask

 

Model

 

M-9520A  

 

Photo

 

 

Intended Use

 

As a respirator, it is intended to help reduce wearer exposure to certain airborne  

particles (solid and liquid aerosols) which are hazardous to health.

 

Reference standard

 

EN 149:2001+A1:2009

 

Classification

 

FFP2   NR

 

Reference regulation

 

Regulation (EU) 2016/425 of the European Parliament and of the Council

 

Component

 

Face Mask Body

Nose Clip

Earloop

Sponge pad 

 

Material

 

Polypropylene non-woven fabrics

 

Specs

 

Maximum penetration of test aerosol : < 6%

 

Total inward leakage

TIL

: < 8% 

 

Inhalation resistance : < 70 Pa at 30L/min, < 240 Pa at 95L/min 

 

Exhalation resistance : < 300 Pa at 160L/min

 

Checks prior to use

 

Before use, check the date of storage of a mask and the technical condition whether a 
mask has no wisible mechanical damage, is not contaminated or incomplete. A damaged 
mask and the one whose storage data has been exceeded cannot be used

 

Usage Method

 

1. Pull an extend the mask inner side to the face with two hands

ensure the nose clip 

is upward.

 

2. Hold the mask on the face and pull the earloop to the ears.

 

3. 

Press the nose clip to fit the shape of the nose.

 

4. 

Check and press the mask fit to the face to minimize leakage. If you cannot achieve 

a proper seal, DO NOT enter the contaminated area. See your supervisor.

 

 

Duration

 

Less than 8 hours is recommended.

 

Reviews: