Instruction for use
12
En
PRO-33 / PRO-35
Common sources of error:
Note:
Comparable blood-pressure measurements always require the same conditions! These are normally always quiet conditions.
All efforts by the patient to support the arm can increase the blood-pressure. Make sure you are in a comfortable, relaxed position
and do not activate any of the muscles in the measurement arm during the measurement. Use a cushion for support if necessary.
If the arm artery lies considerably lower (higher) than the heart, an erroneously higher (lower) blood-pressure will be measured! (Each
15cm difference in height results in a measurement error of 10mmHg)
Cuffs that are too narrow or too short result in false measurement values. Selecting the correct cuff is of extraordinary importance.
The cuff size is dependent upon the circumference of the arm (measured in the centre). The permissible range is printed on the cuff.
Note:
only use clinically approved Original-Cuffs!
A loose cuff or a sideways protruding air-pocket causes false measurement values.
With repeated measurements, blood accumulates in the respective arm, which can lead to false results. Correctly executed blood-
pressure measurements should therefore
fi
rst be repeated after a 1 minute pause.
7.6. Taking your blood pressure reading
For model PRO-33 only
(Picture 5, 5-1, 5-2, 5-3, 5-4)
After applying the cuff and your body is in a comfortable position, press the “START” button. A beep is heard and all display characters
are shown for self-test. See picture 5. Please contact the service center if segment is missing.
a. The LCD will momentarily display the last measurement stored in the memory. See picture 5-1. If the monitor has no meas-
urement stored in the memory, the LCD will display show “0” for blood pressure and pulse rate. See picture 5-2.
Picture 5 Picture 5-1 Picture 5-2 Picture 5-3 Picture 5-4
b. Then the monitor starts to seek zero pressure. See picture 5-3.
c. The monitor in
fl
ates the cuff until suf
fi
cient pressure has built up for a measurement. Then the monitor slowly releases air
from the cuff and carries out the measurement. Finally the blood pressure and pulse rate will be calculated and displayed
on the LCD screen. Irregular heartbeat symbol (if any) will blink. See picture 5-4.
Summary of Contents for PRO-33
Page 2: ......
Page 29: ...29 Fa PRO 33 PRO 35 2 2 1 3 1 5 1 2 2 90mmHg 160mmHg 100 90 160 140 60 100...
Page 30: ...30 Fa PRO 33 PRO 35 ESH 110 180 109 100 160 179 99 90 159 140 89 85 139 130 85 130 80 120...
Page 31: ...31 Fa PRO 33 PRO 35 3 PRO 33...
Page 32: ...32 Fa PRO 33 PRO 35 PRO 35 4 42 22 5...
Page 35: ...35 Fa PRO 33 PRO 35 PRO 33 10 PRO 35 7 2 60 50 240 100 1 2 AD 155...
Page 36: ...36 Fa PRO 33 PRO 35 7 3 7 4 2 1 2 1 5 200...
Page 37: ...37 Fa PRO 33 PRO 35 7 5 15 10...
Page 38: ...38 Fa PRO 33 PRO 35 7 6 4 5 3 5 2 5 1 5 5 PRO 33 5 1 5 0 2 5 3 5 4 5 5 2 5 1 5 4 5 3 5...
Page 39: ...39 Fa PRO 33 PRO 35 2 6 1 6 6 PRO 35 6 1 6 2 6 7 7 6 1 6 2 6...
Page 40: ...40 Fa PRO 33 PRO 35 PRO 35 7 8 2 2 ESH 6 ESH PRO 35 7 9 M 7 7 1 0...
Page 42: ...42 Fa PRO 33 PRO 35 1 7 12 2 7 13 Er 0 Er 1 Er 2...
Page 48: ...48 Fa PRO 33 PRO 35 40 10 50 20 12 3 WWYYXXXX...
Page 53: ...53 Fa PRO 33 PRO 35 800 80 1 2 a PRO 33 PRO 35 PRO 33 PRO 35 PRO 33 PRO 35 3 80 150...
Page 57: ...57 Ar PRO 33 PRO 35 2 2 1 3 1 5 1 2 2 160 90 100 90 160 140 60 100...
Page 59: ...59 Ar PRO 33 PRO 35 3 PRO 33 LCD...
Page 60: ...60 Ar PRO 33 PRO 35 PRO 35 4 42 22 5 LCD...
Page 61: ...61 Ar PRO 33 PRO 35 6 1 5 2 3 4 5 1 5 1 6 3 15 300 7 1 A B 2 3 4 5 8 9 10 11 12 13...
Page 63: ...63 Ar PRO 33 PRO 35 PRO 33 LCD 10 PRO 35 LCD LCD 7 2 60 50 240 100 1 2 155 AD...
Page 64: ...64 Ar PRO 33 PRO 35 7 3 7 4 2 1 2 1 5 200...
Page 65: ...65 Ar PRO 33 PRO 35 7 5 10 15...
Page 67: ...67 Ar PRO 33 PRO 35 2 6 1 6 6 PRO 35 6 1 6 2 6 LCD 1 7 7 6 1 6 2 6...
Page 68: ...68 Ar PRO 33 PRO 35 PRO 35 7 8 35 PRO 2 2 ESH 6 PRO 35 7 9 LCD M 35 PRO 0 LCD 7 1 7...
Page 70: ...70 Ar PRO 33 PRO 35 1 7 12 LCD 2 7 13 LCD Er 0 LCD Er 1 LCD Er 2 LCD...
Page 76: ...76 Ar PRO 33 PRO 35 40 C 10 C 50 C 20 C 12 1 3 Well B WW SN WWYYXXXXX YY...
Page 81: ...81 Ar PRO 33 PRO 35 800 80 1 2 MF MA PRO 33 PRO 35 PRO 33 PRO 35 3 80 150...
Page 83: ...IM_PRO 33_35_EN_FA_AR_0517 B Well Swiss AG Bahnhofstrasse 24 9443 Widnau Switzerland...