YCJSF Series
9
G
AS
C
ONNECTION
The gas connection is male 3/4” BSP and is situa
ted at the rear of the appliance below the main body frame. The
number of gas inlets corresponds to the number of steamer pot/s the appliance is fitted with. The inlet is to the
¾”
elbow located at the rear of the appliance.
The appliance must be connected with a rigid pipe as specified in AS5601. For fixed installation models connect with
20mm copper tube and an AGA approved isolating ball valve.
For models fitted with lockable wheels/castors an AGA approved stainless steel braided flexible hose of adequate
internal diameter must be used. The fitting of the hose must comply with the relevant sections of gas installation code
AS 5601. A restraining chain or wire must be fitted. We recommend a maximum length of 1.5 M for the flexible hose.
When the appliance is in position all of the wheels/castors must have the built-in lock on to prevent any movement of
the appliance. An AGA approved isolating ball valve must also be fitted.
BEFORE CONNECTING NEW PIPE TO THIS APPLIANCE, THE PIPE MUST BE BLOWN OUT THOROUGHLY TO REMOVE
ALL FOREIGN MATERIAL. FOREIGN MATERIAL IN THE BURNER AND GAS CONTROLS WILL CAUSE IMPROPER AND
DANGEROUS OPERATION.
P
RESSURE TEST POINT
All appliances that are dispatched from our factory are tested and adjusted according to the specifications for the
required gas type. The regulator may require adjustment to achieve required gas pressure.
Check the burner pressure at the test point on the regulator. The test point pressure should be adjusted to 1.00 kPa
–
Natural gas or 2.60 kPa
–
LPG with the burners operating at maximum.
W
ATER
C
ONNECTION
The water connection is 15mm copper and is situated at the rear of the appliance below the main body frame. The
number of water inlets varies to client’s
needs. Water isolation valves are fitted to all water inlets. Ensure water is
flushed through before final connection.
Appliances installed with lockable wheels or castors should have appropriate flexi hose (according to the Australian
standards) for water connection.
Water waste outlet is located on the left-hand side of the waste gutter of the appliance (50mm connection). The
water inlets and water drains should be connected with rigid copper pipes. P
lastic/PVC piping should not be used
for connection of waste outlet which will void warranty if done so.
B
EFORE
L
EAVING
-
C
OMMISSIONING
Check
all
connections for gas leaks with soap and water.
Do not
use a naked flame for detecting leaks.
Ignite the pilot and main burners as prescribed below to ensure correct operation of gas valves, burners and ignition.
When satisfied with the operation of the appliance, please instruct the user on the correct method of operation.
Ensure that this instruction manual is left with owner of the appliance.
1.
Light the appliance by pressing in the flame safe guard (blue) button and while holding it in turn the pilot
burner knob anti-clockwise
to “ON”.
2.
Then press piezo button (red button) several times.
3.
Continue to hold in the flame safe guard button for about 25 to 30 seconds.
4.
Check through the observation hole whether the pilot is alight.
5.
If not repeat steps
A.
to
D.
6.
If it is alight turn main burner valve anti-clockwise to
the “ON” position.
7.
Check that burner is properly alight.
In the event the appliance fails to operate correctly, check the following;
•
Data plate to ensure correct gas type and pressure (adjust if necessary)
•
Injector sizes
–
check against data plate and installation manual
•
View pilot size and adjust if required.