Commercial Yum Cha Steamer 

Model No’s.: 

YCJSF-1(2-3) 

 

 Approval No: GMK 10698   

 

 

 

 

Date:17/06/2020 

 

B&S Commercial Kitchens Pty Ltd 

57 Plateau Road Reservoir   VIC   3073 AUSTRALIA 

Tel:

 +61 3 9469 4754   

Fax:

 +61 3 94694504   

Web:

 

www.bscommercialkitchens.com

 

 

Please ensure this booklet is kept in a safe and prominent location for future reference. 

 

The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the 
manufacturer. 
Owing to continual product development and improvements to its products, B&S Commercial Kitchens Pty Ltd reserves the 
right to change the product specifications and design without prior notice. 

 
 
 

 

 

Summary of Contents for YCJSF-1

Page 1: ...Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is s...

Page 2: ...ssure test point 9 Water Connection 9 Before Leaving Commissioning 9 Operating Instructions 10 IMPORTANT WARNING 10 FIGURE 2 YCJSF Series Yum Cha Steamer Knowing Your Appliance 10 Lighting Instruction...

Page 3: ...STANDARD WARRANTY CONDITIONS 15...

Page 4: ...lly and carefully follow the instructions given Ensure that this booklet is kept in a safe and prominent location for future reference 2 Should you be unsure of any aspect of the operation performance...

Page 5: ...Connection Position from Floor mm Position from Rear of Appliance mm Position from LHS RHS edge of Appliance mm Water Inlet W Gas Inlet G Copper 555 5 770 5 95 5 RHS male BSP 250 5 50 5 150 5 RHS Wate...

Page 6: ...HAVE BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE T...

Page 7: ...tural Gas and Propane Gas Please ensure that the gas supply matches the Data Label ensuring that the gas supply is correct for the appliance being installed and that adequate supply pressure and volum...

Page 8: ...iance not covered in table 6 9 600 B Subject to C from a cooking surface area having an open flame cooking appliance and no means of preventing cooking vessels from overhanging the edge of the gas app...

Page 9: ...ection is 15mm copper and is situated at the rear of the appliance below the main body frame The number of water inlets varies to client s needs Water isolation valves are fitted to all water inlets E...

Page 10: ...pes are heavier than air we recommend the operator to also smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operate any electrical switch or phon...

Page 11: ...f and contact B S Commercial Kitchens Pty Ltd or their authorized service agent TELESCOPIC LAUNDRY ARM MANUAL CONTROL The telescopic laundry arm serves the purpose of filling the steamer pot with wate...

Page 12: ...ld detergent to remove any food stuffs oils dust and any other materials 6 The spillage tray located under the control knobs should be removed by pulling out and any carbonized foodstuffs and oils sho...

Page 13: ...hich is accessible from the top after lifting out the steamer pot Undo the two barrel unions just in front of the inlet of the burners and lift out burner 3 The pilot is situated on the left hand side...

Page 14: ...REVERSE ORDER Table 4 Troubleshooting FAULT Pilot light not igniting Pilot light not establishing Pilot established main burner not lighting Telescopic laundry arm constantly running POSSIBLE CAUSE C...

Page 15: ...this appliance please contact manufacturer To obtain further service information concerning this appliance please contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9...

Page 16: ...e has been installed in accordance with local regulations by a duly authorised person and the B S installation instructions provided with the appliance If in doubt please contact B S or their represen...