background image

 

YCJSF Series

 

 

 

14 

1. 

Gently pull down protective sleeve where piezo lead meets pilot electrode.  

2. 

Remove piezo lead from pilot electrode.  

3. 

Undo nut located underneath the pilot electrode on the pilot assembly.  

4. 

Pull electrode downwards.  

5. 

Reassemble in reverse order.  

Reassemble pilot assembly to burner support bar in reverse order 

A

DJUSTMENTS 

 

• 

Pilot 

 

1. 

Remove front panel as described under GAINING ACCESS TO GAS CONTROLS.  

2. 

To  increase  gas  pressure  to  pilot,  turn  adjustment  screw  located  at  the  top  right  hand  side  of  the 

flame failure devise anti-clockwise.  

3. 

To decrease gas pressure  to  pilot, turn adjustment screw located  at the top right hand  side of the 

flame failure devise clockwise.  

4. 

REASSEMBLE IN REVERSE ORDER.   

Table 4: Troubleshooting 

 

 

 

FAULT

 

 

  
   

 

 

Pilot light not igniting 

 

  
   

 

 

Pilot light not establishing 

 

 

 

Pilot  established,  main  burner 
not lighting 

 

 

 

Telescopic 

laundry 

arm 

constantly running

 

 

 

POSSIBLE CAUSE 

 

CHECKS

 

 

  

Blockage of pilot 

 

  

Adjustment of pressure from flame 

failure control 

 

Check pilot injector is not blocked as 

described in servicing instructions 

 

pilot and flame safeguard 

 

 Check gas pressure to pilot as described 
under servicing instructions 

 

adjustments 

 

 

 

Positioning of thermocouple 

 

 

 

Check  connection  of  the  thermocouple 
to the control is not loose. 

 

 

 

Faulty thermocouple 

 

  
  

Faulty flame failure control valve 

 

Adjust  positioning  of  thermocouple  to 

ensure 

pilot 

flame 

is 

hitting 

thermocouple 

 

 
 
Contact manufacturer 

 

  

Position of pilot

 

  

Pressure setting of regulator 

 

Is pot in position

 

Ensure  

Adjust pressure to correct pressure  

 

Check that main pot is in position

 

  

Worn tap washer  

 

 

 

Change washers in tap assembly. 

 

 

  

Summary of Contents for YCJSF-1

Page 1: ...Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is s...

Page 2: ...ssure test point 9 Water Connection 9 Before Leaving Commissioning 9 Operating Instructions 10 IMPORTANT WARNING 10 FIGURE 2 YCJSF Series Yum Cha Steamer Knowing Your Appliance 10 Lighting Instruction...

Page 3: ...STANDARD WARRANTY CONDITIONS 15...

Page 4: ...lly and carefully follow the instructions given Ensure that this booklet is kept in a safe and prominent location for future reference 2 Should you be unsure of any aspect of the operation performance...

Page 5: ...Connection Position from Floor mm Position from Rear of Appliance mm Position from LHS RHS edge of Appliance mm Water Inlet W Gas Inlet G Copper 555 5 770 5 95 5 RHS male BSP 250 5 50 5 150 5 RHS Wate...

Page 6: ...HAVE BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE T...

Page 7: ...tural Gas and Propane Gas Please ensure that the gas supply matches the Data Label ensuring that the gas supply is correct for the appliance being installed and that adequate supply pressure and volum...

Page 8: ...iance not covered in table 6 9 600 B Subject to C from a cooking surface area having an open flame cooking appliance and no means of preventing cooking vessels from overhanging the edge of the gas app...

Page 9: ...ection is 15mm copper and is situated at the rear of the appliance below the main body frame The number of water inlets varies to client s needs Water isolation valves are fitted to all water inlets E...

Page 10: ...pes are heavier than air we recommend the operator to also smell the floor around the appliance In the event you smell gas DO NOT light any appliance DO NOT touch operate any electrical switch or phon...

Page 11: ...f and contact B S Commercial Kitchens Pty Ltd or their authorized service agent TELESCOPIC LAUNDRY ARM MANUAL CONTROL The telescopic laundry arm serves the purpose of filling the steamer pot with wate...

Page 12: ...ld detergent to remove any food stuffs oils dust and any other materials 6 The spillage tray located under the control knobs should be removed by pulling out and any carbonized foodstuffs and oils sho...

Page 13: ...hich is accessible from the top after lifting out the steamer pot Undo the two barrel unions just in front of the inlet of the burners and lift out burner 3 The pilot is situated on the left hand side...

Page 14: ...REVERSE ORDER Table 4 Troubleshooting FAULT Pilot light not igniting Pilot light not establishing Pilot established main burner not lighting Telescopic laundry arm constantly running POSSIBLE CAUSE C...

Page 15: ...this appliance please contact manufacturer To obtain further service information concerning this appliance please contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9...

Page 16: ...e has been installed in accordance with local regulations by a duly authorised person and the B S installation instructions provided with the appliance If in doubt please contact B S or their represen...

Page 17: ...warranty Breakage of pilot knobs knee valve handles and knee wands are not covered under warranty Thermocouples piezo leads and ignitors are only covered by twelve 12 months parts and labour across K...

Reviews: