Figure 1: Plumbing Connections
Table 3: Plumbing Connections
Connection
Position from
Floor
(mm)
Position from
Rear of Appliance
(mm)
Position from
LHS/RHS edge
of Appliance
(mm)
Water Inlet (WI)
Gas Inlet (GI)
½” Copper
298 (+/-5)
759 (+/-5)
273 (+/-5) LHS
¾” male BSP
246 (+/-5)
508 (+/-5)
56 (+/-5) LHS
Over Flow (D1)
1” Hose
749 (+/-5)
693 (+/-5)
187 (+/-5) LHS
Waste (D2)
1” BSP
381 (+/-5)
606 (+/-5)
127 (+/-5) LHS
Plinth mount models have connections 170 mm lower.
Installation Instructions
Regulations
The appliance
must
be installed only by authorised persons and in accordance with the manufacturer’s
installation instructions, local gas fitting regulations, municipal building codes, AS 5601
– Gas Installations
and any other health and safety regulations, local authority, gas, electrical any other statutory regulations.
Data Label
The data label is located on the front of the appliance. This appliance is suitable for Natural Gas and LPG.
Please ensure that the gas supply matches the Data Label ensuring that the gas supply is correct for the
appliance being installed and that adequate supply pressure and volume is available
– refer to appliance
data plate for Mj/hr consumption, injector sizes of main burners/pilots, etc.
Ventilation
It is strongly recommended that the appliance is installed under an extraction hood (with a clearance of
1200mm to the grease filter). Ventilation must be in accordance with AS5601 -
Gas
Installations. In general,
the appliance should have adequate ventilation for complete combustion of gas, proper flueing and to
maintain temperature of immediate surroundings within safe limits.