background image

12 

 

backwards so that burner is clear of the combustion area. 

d.  Reassemble in reverse order. 

 

Gas Valve 

1. 

To remove/change/service main gas valve. 

a.  Undo barrel union on right hand side of gas valve 
b.  Undo flexible tube to main gas valve from burner manifold. 
c.  Undo flexible tube from pilot assembly to main gas valve. 
d.  Undo terminals from thermostat (if fitted) on the main gas valve. 
e.  Undo thermocouple leading into main gas valve 
f. 

Remove piezo igniter as described under PIEZO ASSEMBLY 1. a. above 

g.  Undo mounting screws on the gas valve support bracket. 
h.  Gently remove main gas valve 
i. 

Reassemble in reverse order 

 

Table 4: Troubleshooting 

FAULT 

POSSIBLE CAUSE 

CHECKS 

Pilot light not igniting 

 

 

Blockage of pilot 

 
 

Adjustment of pressure from flame failure 

control 

 

Check pilot injector is not blocked as 

described in servicing instructions 

– pilot 

and flame safeguard 

 

Check gas pressure to pilot as described 

under servicing instructions 

– adjustments 

 

Pilot light not establishing 

 
 
 

Positioning of thermocouple 

 
 
 

Faulty thermocouple 

 
 
 

Faulty flame failure control valve 

 

Check connection of the thermocouple to 

the control is not loose. 

 

Adjust positioning of thermocouple to 

ensure pilot flame is hitting thermocouple 

 

Contact manufacturer or authorised 

service agent 

 
 

Contact manufacturer or authorised 

service agent 

 

Pilot established, main burner 

not lighting 

 

Faulty thermocouple 

 

Faulty Thermopile 

 

Faulty flame failure control valve 

 

Contact manufacturer 

 

Contact manufacturer 

 

Contact manufacturer 

 

Telescopic laundry arm 

constantly running (on 

water/deck cooled wok tables) 

 
 
 

Worn tap washer 

 

Change washers in tap assembly. 

 

Contact manufacturer or authorised 

service agent 

 

 

 

 

Summary of Contents for NC Series

Page 1: ... 61 3 94694504 Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves the rig...

Page 2: ...formation 5 Figure 1 Plumbing Connections 6 Table 3 Plumbing Connections 6 Installation Instructions 6 Regulations 6 Data Label 6 Ventilation 6 Combustible Surfaces 7 Plinth Mount Models 7 Gas Connection 7 Pressure Test Point 7 Water Connection 7 Burner Adjustment 7 Before Leaving Commissioning 8 Operating Instructions 8 IMPORTANT WARNING 8 IMPORTANT WARNING 9 Lighting Instructions 9 Shutdown Proc...

Page 3: ...Abnormal Operation 10 Panel Removing 10 Controls 11 Thermostat 11 Pilot Assembly 11 Piezo Assembly 11 Burners 11 Gas Valve 12 Table 4 Troubleshooting 12 Table 5 Spare Parts List 13 Warranty on B S Commercial Cooking Appliances Error Bookmark not defined ...

Page 4: ...Appliance Name NC Series Noodle Cooker This appliance may be branded as B S Kirana and Verro ManufacturedBy Certificate Holder B S Commercial Kitchen s Pty Ltd 57 Plateau Road Reservoir Victoria 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com ModelNumber s Suppliedinvariousconfigurations Howtoreadmodelnumbers NC 6 R S 2RP SP CF YC P NC 6 Noodle Cooker All Models R S...

Page 5: ...INITY OF THIS APPLIANCE WHILE IT IS IN OPERATION ENSURE ANY TRANSIENT PROTECTION IS REMOVED BEFORE INSTALLING THE APPLIANCE ENSURING ANY POSSIBLE DAMAGE TO THE APPLIANCE OR COMPONENTS PARTS THAT MAY HAVE BEEN SUSTAINED DURING TRANSPORTATION IS REPORTED TO THE MANUFACTURER THIS APPLIANCE IS NOT INTENDED TO BE USED IN A MARINE ENVIRONMENT ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION FAILURE TO...

Page 6: ...ety regulations local authority gas electrical any other statutory regulations Data Label The data label is located on the front of the appliance This appliance is suitable for Natural Gas and LPG Please ensure that the gas supply matches the Data Label ensuring that the gas supply is correct for the appliance being installed and that adequate supply pressure and volume is available refer to appli...

Page 7: ...be and a certified isolating ball valve BEFORE CONNECTING NEW PIPE TO THIS APPLIANCE THE PIPE MUST BE BLOWN OUT THOROUGHLY TO REMOVE ALL FOREIGN MATERIAL FOREIGN MATERIAL IN THE BURNER AND GAS CONTROLS WILL CAUSE IMPROPER AND DANGEROUS OPERATION Connect to gas Pressure Test Point All appliances that are dispatched from our factory are tested and adjusted according to the specifications for the req...

Page 8: ... pressure adjust if necessary 2 Injector sizes check against data plate and installation manual 3 View pilot size and adjust if required In case appliance fails to operate correctly after all checks have been carried out pleased contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com Operating Instruction...

Page 9: ...minutes for any gas in combustion chamber to escape propane gas being heavier than air may require forced ventilation C Observe pilot frame is extinguished Boil Out Procedure 1 Prior to lighting burner ensure noodle cooker drain valve is closed 2 Fill noodle cooker pan with a mixture of cold water and dishwashing detergent up to the bottom of the water level line in the pan 3 Operate the appliance...

Page 10: ...ide out for excessive build up of any fats oils and foodstuffs o Inspect that the burners and other components i e pilots thermocouples etc are in good condition and functioning properly o Inspect all gas connections for leaks and ensure all connections are tightened properly o Ensure burner manifold pressure is in accordance with that specified on the data plate of the appliance o Inspect all gas...

Page 11: ... order 4 To change thermocouple a Undo locking screw holding thermocouple to pilot assembly bracket and gently pull the thermocouple down b Undo thermocouple screw located in the main gas valve c Replace with new thermocouple and assemble in reverse order 5 To change new pilot assembly a Follow steps 1 and 2 b Undo the two screws on the pilot mounting bracket and pilot bracket c Follow procedures ...

Page 12: ...ressure from flame failure control Check pilot injector is not blocked as described in servicing instructions pilot and flame safeguard Check gas pressure to pilot as described under servicing instructions adjustments Pilot light not establishing Positioning of thermocouple Faulty thermocouple Faulty flame failure control valve Check connection of the thermocouple to the control is not loose Adjus...

Page 13: ...ont Stop tap 0581 Thermostat Switch 212 M F Ball Valve 602 Flexitube from Gas valve to pilot 602A Flexitube from Gas Vale to Manifold 036A Piezo Lead 036 Piezo 325 Noodle Basket To obtain further service information concerning this appliance pleased contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com ...

Reviews: