background image

 

IWM-PL4_QUG 

Quick User Guide 

v1.0 

IWM-PL4

 

 

 

 

                                                         

   

 

Pulse module for B METERS water meters 

 

Product description 

 

 

 

 

The IWM-PL4 module is a device that allows to transmit via pulse output the reading data detected 
by the WDE-K50 water meters manufactured by B METERS. 
The  module  must  be  configured  using  an  Android  device  (smartphone,  tablet,  etc.)  with  an  NFC 
interface  and  the  NFC  IWM  Config  application.  This  allows  to  set  the  impulsive  value,  the  various 
operating options and to monitor the status and the alarms. To download the app, please connect to 
the Google Play, type NFC IWM Config and press the button “Install”. Please refer to the configuration 
software manual for a detailed description of the configuration features and options available. A quick 
manual is also available on the app: to consult it, launch the app and press the button “?”. 

 

 

Package Content 

 

IWM-PL4 module 

 

Mounting screw 

 

Anti-tampering sticker 

 

Installation guide 

 

Technical data 

 

Working temperature: From +1°C to +55 °C

 

 

Power supply: Lithium battery  3.6V  Li-SOCI

2

 – 1,65 Ah*

 

 

Maximum battery duration: 10 years**

 

 

Communication interface: Open Collector, polarized – max 30 VDC (100mA)

 

 

Protection level: IP68*** 

 

 

Dimensions (ø x h, without cable): 100 x 43 mm

 

 

Cable length: 1,5 m

 

 

Weight: 160g

 

 

* Batteries are not replaceable, DO NOT ATTEMPT TO REPLEACE. Any attempt will void the warranty, moreover will irreversibly damage 
the device. 
** in ideal operative conditions. 
*** maximum 24 hours of continuous submersion at 1 m depth 

 

 

Installation 

The installation of the module IWM-PL4 is allowed on WDE-K50 meters. 
Install the module on the meter as shown in the picture [1]. It is necessary to combine the hooks of 
the meter with the ones on the module. 
With one hand keep the meter steady, with the other hand push the module gently towards the dial 
[2] and pull it in the direction shown by the arrow [3]. 
Connect the wires as follows: 

 

White [+]: regular count wire, NO contact (Normally Open). The contact closes every time the 
pulse is sent, independently from the water flow direction. 

 

Yellow [+]: tampering wire, NC contact (Normally Closed). The contact opens when one (or 
more) of the following events occurs: 

-

 

Module removal 

-

 

Fraud on the inductive sensor  

-

 

Cable cut 

-

 

Magnetic fraud 

 

Green  [+]:  programmable  wire,  NO  contact  (Normally 
Open). The user can set one of the following functions: 

-

 

Absolute  counting  (closes  when  the  pulse  is  sent,  with  backward  flow  revolution 
compensation; 

-

 

Backward counting (closes when the pulse is sent, when the flow goes backwards); 

-

 

Dosing (closes every “x” liters, with “x” freely programmable). 

 

Brown [-]: Ground (common wire) 

 

Commissioning 

The module must be configured with the Android App (NFC IWM Config). Before proceeding with the 
configuration, make sure that the module is correctly installed on the meter and that the wiring is 
done properly. 
To proceed with the configuration, launch the app on the android device and place it directly on the 
module. Verify the correct data transmission and make sure that the device status is ok and no alarm 
is active. For the complete configuration instructions please check the software documentation. 
For a correct installation of the module on the meter, it is necessary to insert the screw and apply the 
sticker seal in the point shown in the picture [4]. 

 

Step 1 

 

            

Step 2 

 

               

 

Step 3 

 

 

Step 4 

 

 

Safety

 

 

During  the  installation  process,  handle  the  device  with  care,  don’t  crush,  don’t  bent,  don’t 
exposure to electrostatic discharges which could damage permanently the device, do not install 
close to heat sources (radiators, conditioners, convectors etc..). 

 

The  module  doesn’t  contain  hazardous  materials  in  accordance  with  European  directives 
2011/65/UE (RoHS) and subsequent modifications. The device requires specific disposal on the 
end of its lifetime. Recycling is mandatory or recommended following the Directive RAEE inside 
European Union region, or anyway dispose in accordance with local laws and regulations. Do not 
burn, or undergo to high temperatures.  

 

The  IWM-PL4  works  reliably  in  the  environmental  conditions  specified  in  this  manual.  Any 
unauthorized intervention and/or modification may cause malfunctions or total damaging of the 
product. 

 

Warranty 

The warranty period is set at 24 (twenty-four) months from the date of the shipping of the material. 
Warranty  is  against  defects  in  materials  or  workmanship  when  the  product  is  properly  used  and 
maintained  in  normal  efficiency.  This  Warranty  is  valid  and  enforceable  in  the  country  where  the 
product  was  purchased.  In  the  event  that  the  product  has  been  purchased  in  a  country  of  the 
European Union, the warranty is still valid in all countries of the Community. 
 
To obtain warranty service, it is requested to comply with the following clauses:  
1.

 

Products must be delivered for repair at the expense of the customer.  

2.

 

The product warranty will be subject to the exhibition of a tax document (receipt, receipt or 
bill of sale), which attests to the date of purchase of the product.  

3.

 

The repair will not affect the original date of expiration of the warranty and will not involve 
the renewal or extension thereof.  

4.

 

If at the time of the repair, the product has not any defect, it will be charged the costs of the 
technical analysis. 

5.

 

The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the product, 
use of non-original batteries, accidents, product alteration, replacement/detachment of seals 
and/or product tampering. The same also does not cover damage caused during transport if 
packages used are unsuitable.  

6.

 

The warranty is not covering the battery of the product. 

7.

 

The  warranty  does  not  cover  the  inability  to  use  the  product,  other  costs  incidental  or 
consequential damages or other expenses incurred by the purchaser. 

8.

 

The warranty doesn’t cover damage to the product caused by usage in any other way than 
described in this manual. 

 
 

Support on the products 

If  the  product  needs  to  be  sent  to  the  technical  assistance,  contact  your  dealer  or  contact  the 
BMETERS After sales service at 

[email protected]

 

 
 

Declaration of Conformity 

Hereby, B METERS, declares that this IWM-PL4 is in compliance with the essential requirements and 
other relevant provisions of Directive 2014/30/EU. 
The complete declaration can be downloaded from the official websit

www.bmeters.com

 
 
 
 

Contact Info 

 

B METERS Srl 

 

Via Friuli 3 
Gonars (UD) – 33050  
Italy 

Tel: +39 0432931415 
Fax: +39 0432992661 
E-Mail (sales/informations)

[email protected]

  

E-mail (technical support)

[email protected]

 

Web

www.bmeters.com

 

 

 

Summary of Contents for IWM-PL4

Page 1: ...dei dati di lettura e l assenza di eventuali allarmi Per le istruzioni di configurazione complete si rimanda alla documentazione del software Per una corretta installazione del modulo sul contatore ne...

Page 2: ...o IWM PL3 e IWM PL4 della B METERS forniscono delle uscite di tipo Open Collector OC polarizzate di tipo NPN non forniscono un contatto pulito Lo schema di riferimento il seguente Dalla figura si vede...

Page 3: ...ipo Open collector NO CONTATTO PULITO o DRY CONTACT 2 La tensione applicata al contatto sia inferiore a 30V Questa tensione in pratica coincide con la tensione di alimentazione del dispositivo di lett...

Page 4: ...le masse non crea correnti anomale 2 Filo di uscita degli impulsi BIANCO GIALLO E VERDE collegato all ingresso del dispositivo che legge gli impulsi PLC ad esempio Si ricorda che questo ingresso devo...

Page 5: ...neralmente indicati dalla scheda tecnica del rel Procedere dunque nel seguente modo 1 Collegare l ingresso del rel bobina di eccitazione all uscita del IWM PL3 o IWM PL4 come da schema Un terminale de...

Page 6: ...meter it is necessary to insert the screw and apply the sticker seal in the point shown in the picture 4 Step 1 Step 2 Step 3 Step 4 Safety During the installation process handle the device with care...

Page 7: ...lse emitter IWM PL3 PL4 modules with inductive principle provide polarized Open Collector OC NPN type outputs they do not provide a clean contact The reference scheme is the following The figure shows...

Page 8: ...OUR OUTPUT IS 1 Open collector type NO CLEAN CONTACT or DRY CONTACT 2 The voltage applied to the contact is less than 30V This voltage coincides with the supply voltage of the external reading device...

Page 9: ...t create anomalous currents 2 Pulse output wire WHITE YELLOW AND GREEN connected to the input of the device that reads the pulses PLC for example Please note that this input must accept an NPN polariz...

Page 10: ...generally indicated by the relay technical sheet Then proceed as follows 1 Connect the relay input excitation coil to the IWM PL3 or IWM PL4 output as shown in the diagram One terminal of the coil mu...

Reviews: