background image

Water Meters – 

Contatori D’Acqua           

     

User and Installation Manual – 

Istruzioni per l’uso e il montaggio

 

2. Installation – Installazione

2.1 Before installing – Prima di procedere all’installazione

 

1. Before the meter installation  make sure  that the two ends of the

inlet and outlet pipe are perfectly  aligned,  clean  them with the

utmost care (particularly in case of empty pipes) and let the water

run for some time by installing a temporary pipe in place of the

meter.

2. Before  installing  the meter , make sure there is a suitable filter

placed at the inlet and that  clean and undamaged gaskets  are

inserted on both sides

.

3. Upstream and downstream the meter install appropriate water flow

interception and regulation devices suitable to allow inspection and

maintenance of the meter, control of the water flow and eventual

sealing of the system. We also recommend to install a non-return

valve to prevent back flow.

4. Attention must be paid to the direction of the flow. Install the meter

so that the water flow follows the direction indicated by the arrow

embossed on the meter body.

Install the meter respecting the position recommended by 

Bmeters

(in accordance with the indication on the dial of the meter itself).

1. Prima dell'installazione del contatore, verificare che i due tronchi

della tubazione siano in asse, pulirli con la massima cura (in

particolare  nel caso di tubazioni vuote) e lasciare scorrere l'acqua

per qualche tempo utilizzando un tubo d’attesa  installato al posto

del contatore.

2. Prima di montare il contatore, verificare che sul lato di ingresso del

flusso sia presente un filtro idoneo e che siano inserite guarnizioni

pulite ed integre su entrambi i lati.

3. Installare a monte ed a valle del contatore opportuni dispositivi di

intercettazione e regolazione del flusso idrico idonei a consentire le

operazioni di manutenzione e di verifica del contatore, di controllo

della rete idrica e di sigillatura dell'impianto. Si consiglia,  inoltre,

l'installazione di una valvola di non ritorno.

4. Occorre prestare attenzione alla direzione del flusso. Installare il

contatore in modo che il passaggio dell'acqua avvenga nel senso

indicato dalla freccia in rilievo sul corpo del misuratore e rispettando

la  posizione consigliata da 

BMeters 

(in  accordo a quanto indicato

sul quadrante del contatore stesso).

Summary of Contents for GSD534AF

Page 1: ...Supplied by Call us on 44 0 118 916 9420 Email info 247able com com Installation Maintenance Instructions B METERS Metering Solutions...

Page 2: ...User and installation manual Istruzioni per l uso ed il montaggio...

Page 3: ...dei contatori d acqua 3 2 Installation Installazione 4 2 1 Before installing Prima di procedere all installazione 2 2 Single jet Water Meters Contatori Getto Singolo 6 2 3 Multi Jet Water Meters Conta...

Page 4: ...and flow rates A prolonged overload could cause an irreparable damage to the meter internal components To the contrary an operating flow rate lower than the minimum flow may not allow a proper meterin...

Page 5: ...d on the meter body Install the meter respecting the position recommended by Bmeters in accordance with the indication on the dial of the meter itself 1 Prima dell installazione del contatore verifica...

Page 6: ...e that the pipe is completely full and that there is no air inside 7 Make sure that the meter is installed in a place protected from impact or tampering and that is not subjected to hydraulic effects...

Page 7: ...bile comunque l installazione orizzontale con l asse della turbina perpendicolare al suolo e l orologeria rivolta verso l alto 2 3 Multi jet Water Meters Contatori Getto Multiplo All BMeters multi jet...

Page 8: ...ompletamente l aria dalla tubazione e dal contatore stesso Durante la messa in servizio aprire lentamente le valvole di chiusura per evitare forti sbalzi di pressione Controllare infine che il contato...

Page 9: ...of consumption data recorded For installation and configuration instructions refer to the Hydrolink system manuals I contatori d acqua versione RFM possono essere abbinati al sistema di telelettura Bm...