WIRING DIAGRAM

  Pull branch circuit wiring. Make watertight 

connections from primary branch circuit to pre-

wired 12ga solid wire receptacle leads using 

waterproof wire connectors (by others). Connect 

incoming ground and ground from receptacle to 

ground wire on base.

 See wiring diagram.

WIRING DIAGRAM - 0-10

 

Pull branch circuit wiring. Make watertight 

connections from primary branch circuit to 

pre-wired 16/5 round jacketed fixture head 

leads using waterproof wire connectors 

(by others). Connect incoming ground and 

ground from receptacle to ground wire on 

base. 

See wiring diagram.

WIRING DIAGRAM - INC

  Pull branch circuit wiring. Make watertight 

connections from primary branch circuit to pre-

wired 16/3 round jacketed fixture head leads 

using waterproof wire connectors (by others). 

Connect incoming ground and ground from 

receptacle to ground wire on base.

 See wiring 

diagram.

RECEPTACLE INSTALLATION DIAGRAM

FIXTURE INSTALLATION DIAGRAM

7.  Mount base and plate to concrete using mounting 

holes drilled previously (mounting hardware by 

others). Minimum 1/4” diameter sleeve or wedge 

anchors for concrete must be used.

9.  Seal base and plate as per NEC. Continue with 

installation of receptacle option chosen.

8.  Tighten four (4) #10-32 screws in base 

using a 3/32” allen wrench to secure to 

installed PVC housing.