background image

Warning

High Voltage

Hot Surface

 

Patented HydroLock®  

Barrier Plate  

Assembly (ACV™)

Cutoff Glare 

Shield

O-Ring

Patented  

Stability  

Flange

1/8” Allen Wrench
Phillips Screwdriver
Level
Hammer

NEEDED

FOR 

INSTALLATION:

By Others

OptiLock®

Faceplate

RELEASE DATE

12-9-16

REFERENCE

 

NUMBER

INS-1367-00

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

• 

Product must be installed by a qualified person in a manner 

consistent with its intended use and in compliance with the 

National Electrical Code, Canadian Electrical Code, and all Local 

and Provincial Codes. 

• 

Follow product label information and instructions.

• 

Qualified Personnel must perform all servicing or relamping of 

this product.

•  Before wiring to power supply and during servicing or 

relamping, turn off power at fuse or circuit breaker before 

service.

• 

The use of accessory equipment not recommended by the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause 

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

an unsafe condition and void product warranty.

• 

Do not block light emanating from product in whole or part, 

as this may cause an unsafe condition.

• 

Never operate the fixture with missing or damaged lens.  

Lens must be cleaned on regular basis.

• 

Entire fixture may become extremely hot. Do not touch hot 

lens or fixture body. Do not touch the lamp at any time. Use 

a clean, dry, soft cloth to handle the lamp. Oil from skin may 

damage the lamp and cause it to rupture.

• 

Replace lamp only with correct wattage and type of lamp 

marked on fixture label.

• 

All gaskets, o-rings and sealing surfaces must be kept clean 

during installation and service; failure to do this may cause 

an unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted lamp is HOT!

WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:  

Turn off/unplug and allow to cool before replacing lamp.  

Lamp gets HOT quickly! Contact only switch/plug when 

turning on.  

Do not touch hot lens, guard, or enclosure (see diagram/

picture).  

Keep lamp away from materials that may burn.  

Do no touch the lamp at any time. Use a soft cloth. Oil 

from skin may damage lamp.  

Do not operate the luminaire fitting with a missing or 

damaged shield.  

 

SAVE THESE INSTRUCTIONS

 

·  Suitable for wet locations

IMPORTANT LISTINGS AND CERTIFICATIONS

Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.

Quick Disconnect

DR

2

 SERIES

Deep Housing - Metal Halide (T6)

Remote Ballast Installation Instructions

Waterproof Wire 

Connectors

REMOTE WIRING

Remote ballast installations require inter-connected wiring 

between the lamp and ballast (by others) and have specific 

wiring requirements between these components. Ballast 

manufacturers regularly recommend the following wiring 

details for such installations.

Electronic Ballast

•  1 Foot Minimum and 15 Foot Maximum Remote 

Wire Length (Ballast to Lamp Socket). 

•  Lamp leads must be run in a separate, dedicated 

metal conduit. 

•  Lamp leads must be 18 gauge, wire type SF-2 or 

SFF-2.

•  Lamp leads must be placed in a minimum 1/2” 

internal diameter conduit, pipe, or flexible 

conduit.

•  The use of metal clad cable assemblies or service 

power cords (SJ, SO, etc.) is prohibited.

Magnetic Ballast

•  35 Watt = 15 Foot Minimum and 50 Foot Maximum 

Remote Wire Length (Ballast to Lamp Socket).

•  >35 Watt = 1 Foot Minimum and 50 Foot 

Maximum Remote Wire Length (Ballast to Lamp 

Socket).

Please consult the factory through your local B-K Lighting 

Sales Representative prior to finalizing any installation detail 

utilizing remote ballast wiring.

 

Failure to comply with specific wiring 

requirements will void product warranty.

DR2 Housing

Summary of Contents for Precision2 DR2 Series

Page 1: ...with correct wattage and type of lamp marked on fixture label All gaskets o rings and sealing surfaces must be kept clean during installation and service failure to do this may cause an unsafe condition and void product warranty INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted lamp is HOT WARNING To reduce the risk of FIRE OR INJURY TO PERSONS Tu...

Page 2: ...allation of faceplate Flush with finished grade 5 Raise housing on EMT so housing is flush with finished grade Use a level to aid in leveling housing 6 When housing is level tighten screws on Patented Stability Flange to secure housing to EMT Remove excess EMT as needed Housing 4 Insert 4 pieces of EMT conduit through the Patented Stability Flange Hammer into substrate until secure Leave sufficien...

Page 3: ...Barrier Plate clockwise to lock Patented HydroLock Barrier Plate must be completely seated to ensure proper seal or water may intrude This step must be done as stated or you will void your warranty 5 Connect optical assembly to Patented HydroLock Barrier Plate with quick disconnect IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS PROJECT ...

Page 4: ...ool to install screws Do not exceed 40 in lbs DR2 SERIES Deep Housing Metal Halide T6 Remote Ballast Installation Instructions 6 Place optical assembly in housing resting the OptiLock on the pins provided inside the housing Align keyhole notch under one 1 of three 3 8 screw heads Tighten screw heads with Phillips screw driver Install proper T6 metal halide lamp 8 Install cutoff glare shield by squ...

Reviews: